Assembling a mechanical seal M1
1 Make sure the stub shaft (2200) is not damaged. If it is, replace it.
2 Place the electric motor with the shaft upright.
3 Put the pump cover flat down and press the counter-ring of the seal straight into it. If
necessary, use a plastic pressure piece.
Never hammer it inside!
The maximum
axial turn of the counter-ring is 0,1 mm.
4 Mount the pump cover in the right position in the collar of the lantern piece. Check
whether the pump cover is at right angles to the stub shaft.
5 Push the rotating part of the mechanical seal on the distance sleeve (1100).
Put
some glycerine or silicon spray on the bellows to facilitate the assembly!
6 Pump size 200-160 only: Push the rotating part of the mechanical seal and the
spacer sleeve (1200) on the the stub shaft.
7 Pump size 200-160 only: Set the distance between the spacer sleeve and the shaft
collar at
44 mm
. Fix the spacer sleeve by means of set screw (1260). See figure 12.
8 Mount the impeller, see paragraph 7.4.2 "Mounting the impeller".
Figure 12:
Adjusting the mechanical seal M1 of pump size 200-160.
4
4
5.
3
9
0
0
2
1
0
6
2
1
4410_A
Summary of Contents for SPX Flow CombiLineBloc
Page 2: ......
Page 6: ...4 INT EN 1512 1 2 ...
Page 10: ...8 CLB EN 1901 6 6 ...
Page 14: ...12 Introduction CLB EN 1901 6 6 ...
Page 26: ...24 General CLB EN 1901 6 6 ...
Page 44: ...42 Disassembly and assembly CLB EN 1901 6 6 ...
Page 50: ...48 Dimensions CLB EN 1901 6 6 ...
Page 56: ...54 Parts CLB EN 1901 6 6 ...
Page 66: ...64 ORDFORM 1512 3 3 EN ...