CL-CBH/EN (1901) 7.6
Disassembly and assembly
41
CombiLine-CombiBlocHorti
7.9.3
Pull-out unit
1 If the studs (0800) were dismantled, screw them into the pump casing (0100).
2 Grease the outer rim of the impeller entry with Molycote 107.
3 Grease the sealing collar of the lantern piece with Molycote 111 and place the O-ring
(0300) in the groove.
4 Mount the Back Pull Out-unit into the pump casing and tighten the fastening nuts
(0810) crosswise.
5 Check whether the shaft end can be rotated, using a screwdriver in the hole of the fan
cover.
Figure 9:
Pump casing with studs.
0100
0800