38
Disassembly and assembly
CL-CBH/EN (1901) 7.6
7.6
Disassembling the electric motor
The item numbers used refer to figure 17 on page 59.
7.6.1
Electric motor stator
1 Put the electric motor vertically with the shaft end pointing downward. Let the motor
flange rest on e.g. 2 wooden blocks with an opening in the working surface for the
shaft end.
2 Remove the fan cover (2420-1) by loosening the 4 screws.
3 Remove the cooling fan (2420-2). For electric motors from 2,2 kW you must first
loosen 2 clamping screws. After that, remove the fan from the shaft end by means of
2 broad screw drivers, see figure 8.
4 Loosen the 4 tie rods (2420-3).
5 Carefully lift up and remove the rear bearing shield (2420-4) by means of two broad
screwdrivers.
6 Remove the wave spring (2420-5).
7 Carefully lift up the stator (2420-6) by means of 2 broad screw drivers and remove it
in vertical direction.
7.6.2
Electric motor bearings
1 Remove the inner circlip (2420-7).
2 Knock on the shaft end, using a plastic hammer, to loosen the shaft (2420-8) with
bearing from the bearing seat of the front bearing shield (2420-11).
3 Remove both bearings (2420-9) using a proper bearing puller. First remove possible
paint from the shaft.
4 Remove the oil-baffle (2420-10) from the rear and front bearing shield (2420-4) and
(2420-11) respectively.
Figure 8:
Removing the cooling fan.
4005
Summary of Contents for SPX Flow CombiBlocHorti Series
Page 2: ......
Page 6: ...4 INT Horti EN 1512 1 2 ...
Page 10: ...8 CL CBH EN 1901 7 6 ...
Page 14: ...12 Introduction CL CBH EN 1901 7 6 ...
Page 28: ...26 Commissioning CL CBH EN 1901 7 6 ...
Page 34: ...32 Faults CL CBH EN 1901 7 6 ...
Page 44: ...42 Disassembly and assembly CL CBH EN 1901 7 6 ...
Page 54: ...52 Dimensions and weights CL CBH EN 1901 7 6 ...