13
※
Console
Error
code
E01 E02 E03 E04 E05
E06
1
:
E01:
A: E01: Communication error between the console and controller when start machine.
B: Solution:
Check the 4 core wire connection between console and the controller whether
unconnected or damaged. if the connecting line is firm, replace the IC board or the
controller board to check whether it is the problem of the controller, or not, replace the
console or IC if also appears E01.
2
:
E02:
A: E02: Controller does not detect the voltage of the wires of DC motor
B: Solution
:
Check the positive and negative wires on the motor to see if the connection is firm with
the terminals of controller. if connection is ok, please check all the components of
controller to see if there is any damaged like power tube, or replace the controller or
motor.
3
:
E03:
A: E03: the controller cannot detect the speed feedback signal when motor running.
B: Solution
:
1) check the motor to see if it starts, if it runs but then stops and shows E03, Please check
whether the optical sensor is plugged disconnected or damaged. If all is in order
change the optical sensor or replace controller and IC board.
2) If the motor does not run and shows E03 when starting, please check whether the motor
is jammed or damaged..
4
:
E04:
A: Incline self-learning fault
B: Check incline motor sensor wire and AC wire are inserted correctly; AC wire is correctly
inserted according to the identify in the incline motor; make sure the incline motor wire is
not damaged; after checking, press the button on controller, then start self-learning
again.
5
:
E05:
A: E05: The current is larger than the current protection when the motor is running
B: Solution:
Check whether the motor is abnormal or damaged; check whether there is any objects
under the running belt
、
roller lead the rotational resistance increase. If there’s no problem,
please replace the controller.
If any other questions, please ask help from local distributors or our after-sales service
department.
5
:
The console display “
— — —
”:
A: “— — —”stands for the console cannot received the signal from the safety lock.
B: Solution: Check the safety magnet is in the correct position. Open the console cover, Check
the safety switch line if plug is firm, Safety switch board is damaged or Safety switch fixed