AB5 and AB51 Drivers User Manual
Technical Data
Nanomotion Ltd.
43
I/Os
5.5
Opto-isolated Inputs
5.5.1
The following inputs are opto-isolated and are active “low”, i.e. by
shorting them to ground (see
Table
8 for more details):
•
Emergency_Stop:
disables driver’s output.
•
Enable_Sign_In:
changes Enable input logic to active “high”.
•
Enable:
enables driver operation; should be activated before
operating the motor.
•
Step_Mode:
enables Step mode operation
•
Brake_On:
disables driver’s output.
•
Set_Offset:
adjust 0 (zero) command level.
Figure 12: Opto-Isolated Input Interface
To Control
Logic
Vcc
AB5/AB51
390
Ω
Jumper 3
1
Vcc
User Voltage
Command Input
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com