Johnson Controls VA9905 Series Installation Instructions Manual Download Page 2

14-88360-03206, Rev. A

Contents

Compliance Information............................................................................1

About This Document ...............................................................................1

Accessories ..............................................................................................1

Support Information ..................................................................................1

Parts Included...........................................................................................2

Tools Required..........................................................................................2

Flow Disk Set............................................................................................3

Installing the Six-Way Valve to a System .................................................4

Clearance Required to Install an Actuator ................................................4

Attaching the Actuator to the Six-way Valve .............................................5

Setting the DIP Switches ..........................................................................6

Wiring the Actuator ...................................................................................6

Manual Override and Flow Direction ........................................................7

VA9905 Technical Specifications

 ..............................................................8

VG1600 Valve Series Technical Specifications

 ........................................9

Compliance Information

IMPORTANT

:

 

Use this VA9905 Actuator only to control equipment under normal operating conditions.

Where failure or malfunction of the VA9905 Actuator could lead to personal injury or property damage to the con-

trolled equipment or other property, additional precautions must be designed into the control system. Incorporate 

and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or 

protect against failure or malfunction of the device.

IMPORTANT :

 Utiliser ce [nom complet de l’appareil] uniquement en tant que dispositif de contrôle de

fonctionnement. Lorsqu’une défaillance ou un dysfonctionnement du [nom abrégé de l’appareil] risque de

provoquer des blessures ou d’endommager l’équipement contrôlé ou un autre équipement, la conception du

système de contrôle doit intégrer des dispositifs de protection supplémentaires. Veiller dans ce cas à intégrer de

façon permanente d’autres dispositifs, tels que des systèmes de supervision ou d’alarme, ou des dispositifs de

sécurité ou de limitation, ayant une fonction d’avertissement ou de protection en cas de défaillance ou de

dysfonctionnement du [nom abrégé de l’appareil]. 

About This Document

This guide describes how to install and configure the VA9905 Actuator and Six-Way Valve. The procedures in this 

guide must be completed sequentially, as they are listed. 

Accessories 

(order separately) 

Code Number Name

Description

VG1600-01 

Wall Mounting Bracket Kit

Provides a mounting bracket for the VA9905 Actuator. 

VG1600-02 

  

Flow Disk Kit

Provides replacement flow disks.

VG1600-03

Insulation Shell Kit

Provides valve insulation.

VG1600-04

Sweat Union Fitting Kit

Provides sweat union fittings.

M9300-100

Conduit Adapter Kit (5 per kit) Provides a conduit adapter that protects the input cable.

Support Information

European Single Point of Contact:

NA/SA Single Point of Contact:

APAC Single Point of Contact:

Johnson Controls

Johnson Controls

Johnson Controls

Westendhof 3

507 E Michigan Street

C/O Controls Product Management

45143 Essen

Milwaukee WI 53202

No. 22 Block D, New District

Germany

USA

Wuxi Jiangsu Province 214142
China

1

Summary of Contents for VA9905 Series

Page 1: ...14 88360 03206 Rev VA9905 Actuator and VG1600 Series Six Way Valves Installation Instructions...

Page 2: ...s ou d endommager l quipement contr l ou un autre quipement la conception du syst me de contr le doit int grer des dispositifs de protection suppl mentaires Veiller dans ce cas int grer de fa on perma...

Page 3: ...14 88360 03206 Rev A Parts Included Tools Required 8mm 5 16 in slotted screwdriver or a TORX T 20 driver Two Flow Disk Sets VA9905 Actuator VG1600 Series Valve Two Ring Nuts 2...

Page 4: ...ed disks with hot water only Flow restriction disks have markings that indicate the rate of restriction they provide Using the supplied restriction disks you can set the following flow rates in ports...

Page 5: ...Source 2 return Controlled by the orange wire The diagram below illustrates the input and output flows for the 6 way valve Use this diagram as a guide on how to install the 6 way valve to your system...

Page 6: ...override button on the actuator AC 24 V DC 0 2 10V BLK RED GRY ORN 1 2 3 4 Move the actuator lever to the extreme right position 3 Align the top of the 6 way valve to the plate at the back of the actu...

Page 7: ...dip switch 1 to the ON position or 0 to 10 V Push dip switch 1 to the OFF position Wiring the Actuator Wire Color Input Black Com 24 V AC DC Red Gray Source 1 control Y1 DC 0 2 10 V Orange Source 2 co...

Page 8: ...ctuator to a Six way Valve section sets ports 1 and 4 to full flow Note The ball valve and actuator pointer rotate in opposite directions The following illustrations indicate lever position and flow F...

Page 9: ...11AF 0 7 Kg 1 55 lbs VG1641AF 0 8 Kg 1 85 lbs VG1671AF 1 Kg 2 20 lbs Actuator VA9905 0 8 Kg 1 75 lbs Compliance United States UL Listed CCN XAPX File E27734 to UL 60730 1 Automatic Electrical Controls...

Page 10: ...alve Body with Male BSPP Thread external Valve Body with Female NPT Thread internal Sweat Union Fitting kit Flow coefficient Flow control disk Leakage rate A 100 000 cycles in iron oxide contaminated...

Reviews: