Reader outputs
The controller has four open-collector, switch-to-ground outputs. Use the reader outputs to give the
user visual or audible feedback about ongoing access events. The outputs include three LEDs (LED,
OUT1, and OUT2) and a buzzer (BUZ).
Reader interfaces
The controller has two onboard 12 VDC reader interfaces. You can program them for Wiegand or
ABA clock and data readers.
Note:
For UL listed installations, use only Wiegand, Kantech XSF, MIFARE PLUS EV1, and ISO/
IEC 14443A and 14443B readers and cards.
Integration interface
The KT-1 supports alarm panel interfacing when you make the appropriate connections between
zone inputs, relay outputs, and the alarm system panel.
The KT-1-PCB supports integration interfacing using RS-232 for fire alarm panel and intrusion
integrations.
Note:
RS-232 interface communication with a fire alarm panel has not been evaluated by UL.
Detecting ports automatically
The controller automatically detects the site communication speed set by EntraPass and the
communication port, IP (ETHERNET), or RS-485 (COM1).
Downloadable firmware
The steps to download firmware depend on the mode of your controller. See the following options.
Downloading firmware in EntraPass mode
•
Download firmware from any EntraPass workstation to the controller. The system stores the
firmware in the controller’s flash memory, and it upgrades without having to change any
parts.
Downloading firmware in stand-alone mode
1.
.
2.
Go to
Support
>
Software Downloads
>
Door Controllers and Readers
>
KT-1
.
3.
Select the appropriate firmware version.
Trouble and reporting
The controller monitors its power continuously and reports low and critical power issues. The
controller monitors the power outputs and electronically protects them against short-circuits and
surges. The controller monitors locking devices for short circuit faults.
Technical specifications
The following table lists the technical specifications of the KT-1 controller.
Table 6: Technical specifications
Item
Description
DC power input
11.3 VDC-14 VDC, 1.5 A
Note:
This is compatible with the KT-PS4085 power supply module.
Use the PTC1640UG plug-in adapter model. Standby power: 12 V/7
Ah battery provides 4h of battery backup.
PoE
13 W, 1 A. See Note 1.
PoE+
25.5 W, 1.9 A. See Note 1.
16
KT-1 One-Door Controller Installation Guide
Summary of Contents for Tyco KT-1
Page 1: ...KT 1 One Door Controller Installation Guide D29008966R009 2021 03 08 DN2186 2103 ...