Red LED
Operation
Module Power Up:
Onsteadyduringmodule power-upsequence thenoff.
Firmware Update:
Slow flashing = update in progress
Rapid flashing = update failed
Trouble Condition:
l
No trouble: 1 rapid flash every 10 seconds.
If troublesare present, a seriesof flashesoccur every2seconds.
Eachseriesof flashesindicate troublesasfollows:
l
1 flash: Module not enrolled
l
2 flashes: Loss of contact with module for over 60 seconds
l
3 flashes: Corbus low voltage
l
8 flashes: RF interference (jam condition)
Module Confirmation:
Flashesrapidlyduringmodule confirmationprocess.
PlacementTest:
Onsteadywhenlocationisbad. Off whenlocationisgood.
Green LED
Operation
PlacementTest:
On steady when location is suitable. Off when location is unsuit-
able.
Note:
For UL/ULC listed systems, signal must be “Strong”. See
Wireless Device Status Indications on page 10 for details.
Introduction
The
HSM2HOSTx
two-way
wireless
transceiver
adds
wireless
capability
to
alarm
controllers,
models
HS2016, HS2032, HS2064, HS2128, HS3128, HS3032, and HS3248
.
This
manual
describes
how
to
install,
program
and
maintain
the
HSM2HOST.
Note
that
only
one
HSM2HOST
or
one
RFK
keypad
can
be
enrolled
on
the
alarm
system.
Controls
and
indicators
Status
LEDs
The
LEDs
on
the
front
of
the
HSM2HOST
provide
feedback
regarding
the
installation,
operation
and
troubleshooting
of
the
unit.
The
LEDs
function
as
follows:
Table
1:
Status
LEDs
Tamper
The HSM2HOST has built-in wall and case tampers. The tamper function is disabled by default on the
NA version (enabled on the EU version). Section [804][810] option 3 on page 10 enables or disables the
tamper function. The case tamper activates when the case is opened and restores when the case is
closed. The wall tamper on the back of the unit is depressed by the mounting surface when properly
installed. If the unit is removed, the tamper activates. Ensure the mounting surface is smooth and free
of obstructions that block access to the rear of the unit. Electrical wires should not run over or under the
module when it is mounted.
Note:
The built in wall and case tamper must be installed and enabled for UL/ULC listed Commercial/
Residential Burglary applications.
- 6 -