8.2 Before
Contact
Refer to the information below before contacting a contractor.
Trouble
Check Point
Action
Operation Unavailable
Check that the main power
source is turned ON.
Turn ON the main power source for the air
conditioner.
Check that the fuse is not
blown out or the circuit
breaker of the main power
source tripped.
Replace the fuse or reset the circuit breaker.
If the trouble recurs, contact your contractor or
distributor.
Immediate
Shutdown after
Start-up
Cooling
Check that the air inlet and
outlet of the outdoor unit are
not covered with paper, vinyl
or other objects.
Remove objects covering the air inlet and outlet.
Heating
Check for any obstacles
SUHYHQWLQJWKHDLUÀRZQHDU
the air inlet and outlet of the
outdoor unit.
5HPRYHWKHREVWDFOHVSUHYHQWLQJWKHDLUÀRZ
Check that the outlet air is not
short-circuited to the air inlet.
,QVXI¿FLHQW&RROLQJRU
Heating
Check that the operation
mode is correct.
If the fan mode is selected, switch the operation
mode to cooling or heating.
Check that the set
temperature is correct.
If not, change the set temperature by pressing “ ”
or “ ” by the wired controller.
&KHFNWKDWWKHDLUÀRZ
direction is correct.
,IQRWFKDQJHWKHDLUÀRZGLUHFWLRQ
In the case that the footing is not heated well during
the heating operation, change the louver downward.
&KHFNWKDWWKHDLU¿OWHULVQRW
clogged.
&OHDQWKHDLU¿OWHU
Check that a window or a door
is not opened.
Close the window or the door.
Check for any obstacles
SUHYHQWLQJWKHDLUÀRZQHDU
the air inlet and outlet of the
indoor and outdoor units.
Remove the obstacles.