background image

Part No. 24-11256-00007, Rev. —

5

NS8000 Series

Applications

Icon

Description

1

Humiditiy indicator icon

2

Humidity measurement

3

CO

2

 measurement

4

Configurable setpoint or current temperature

5

Setpoint indicator icon

6

Fahrenheit icon

7

Celsius icon

8

Percent relative humidity icon

9

Fan speed bars

10

Fan icon

11

Automatic fan speed icon

12

Up adjustment or navigation icon

13

SA bus online indicator

14

Down adjustment or navigation icon

15

Menu or enter icon

16

Occupancy indicator

17

Default display value (setpoint, zone temperature, relative humidity)

1

2

3

4

5

6

7
8

11

12

13

14

15

16

17

9

10

Table 1:  Display icons

Summary of Contents for NS Series

Page 1: ...mpliance United States This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and us...

Page 2: ...ence Height requirements may vary depending on the site Network sensors without CO2 sensing are shock and vibration resistant but not shock and vibration proof Be careful not to drop the unit or mount it where it could be exposed to excessive vibration Dropping a CO2 network sensor may result in readings outside of the specified accuracy tolerance Special tools only one type needed Johnson Control...

Page 3: ...dhere to these wiring details causes the network sensor to function incorrectly You will not be able to connect to the system using the Bluetooth Wireless Comissioning Converter BTCVT Mobile Access Portal Gateway MAP or the handheld VAV balancing tool and you will not be able to expand the system with future offerings Notes IMPORTANT Do not connect the SA bus ground the modular phone jack GND or t...

Page 4: ...Part No 24 11256 00007 Rev 4 NS8000 Series 5 2 1 4 15 VDC COM 15 VDC 1 2 5 6 4 3 COM SA SA SA SA COM 15 VDC 3 ...

Page 5: ...r icon 6 Fahrenheit icon 7 Celsius icon 8 Percent relative humidity icon 9 Fan speed bars 10 Fan icon 11 Automatic fan speed icon 12 Up adjustment or navigation icon 13 SA bus online indicator 14 Down adjustment or navigation icon 15 Menu or enter icon 16 Occupancy indicator 17 Default display value setpoint zone temperature relative humidity 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 9 10 Table 1 Displ...

Page 6: ...he home screen complete the following steps 1 Press and hold the Up and Down icons for five seconds until the Fahrenheit and Celsius indicator icons start to blink All icons are visible on the display 2 Press the Menu icon once 3 To select and switch between current temperature or setpoint value press the Up or Down icon 4 To save the new settings press the Menu icon five times to return to the ho...

Page 7: ... it is the proper field to enter the hPa value found in Table 3 Refer to the Controller Tool Help LIT 12011147 for more details Note Enter the pressure value only in units of hPa The sensor reads the value entered as hPa The CO2 present value may require several minutes to settle after changing the offset value See Table 3 for local altitude values Network sensor addressing Table 2 Network sensor ...

Page 8: ...earest customer service center or Johnson Controls representative Altitude above sea level Absolute pressure Feet Meters hPa 656 200 1 038 0 0 1 013 656 200 989 1 312 400 966 1 969 600 943 2 625 800 921 3 281 1 000 899 3 937 1 200 877 4 593 1 400 856 5 249 1 600 835 5 906 1 800 815 6 562 2 000 795 7 218 2 200 775 7 874 2 400 756 8 530 2 600 738 9 186 2 800 719 9 843 3 000 701 Table 3 CO2 altitude ...

Page 9: ...H noncondensing 85 F 29 C maximum dew point Storage Display models 40 F to 122 F 40 C to 50 C 5 to 95 RH noncondensing Non display models 40 F to 185 F 40 C to 70 C 5 to 95 RH noncondensing Temperature resolution 0 5 F 0 5 C Temperature accuracy NS Series Network Zone Sensor 1 F 0 6 C Temperature element only 0 36 F 0 2 C at 70 F 21 C Humidity element accuracy NSB8BPN24x 0 models 2 RH for 20 to 80...

Page 10: ...ulse voltage 330 V External power supply Intended for connection to Johnson Controls field controllers supporting the standard JCI SA Bus implementation CO2 sensor information The Model NSx8 Series Wall Mount sensors sense in part CO2 This functionality is intended to provide an input to equipment under normal operating conditions Where failure or malfunction of the transmitter could lead to perso...

Reviews: