User Manual: NEO System
21
Rev.0.3
Marking
Description
Type
Signals
Activation
20-28V
Emergency Power Supply Input
Input
+
-
20 - 28V DC
Maximum Power: see technical data (Chapter )
Table 12 - Emergency Supply Input
2.4.6 Speaker Lines
a)
Spare Channels Input
The equipment has 8 input back-up amplifier channels
per each internal amplifier. Each connection has two
ter and – where the redundant amplifier output
will be connected. The redundant amplifier must be a
100V line public address amplifier with a minimum
power equal to the nominal channel amplification
power of the equipment. For more information about
the connection of back-up amplifier, see chapter 4.5
The connection is made with a 2-pin female euroblock
connector and pitch 5.08 mm (supplied with the unit).
The wire size range for each pole of this connector is:
0.5
→
2.5 mm2 (22
→
12 AWG).
Marking
Description
Type
Signal
Activation
SPARE CH
INPUTS
X
Input amplification channel corresponding to the
channel reservation amplification equipment X
Input
+
-
NA
Table 13 - Spare Channel Inputs
b)
Speaker Line Output
The equipment has between 4 and 8 amplification channels, each channel has two
speaker line outputs marked as A and B. The rated power of the amplifier channel is
divided between both output lines. For more information about the connection of the
speaker lines see chapter 4.6. Each line connection has two + and - terminals for
connecting speakers to 100V or low-impedance depending on the model.
Figure 24 - Speaker Line Outputs
The connection is made by euroblock female connector and 2-pin pitch 5.08 mm (supplied
with the unit). The wire size range for each pole of this connector is: 0.5
→
2,5 mm2 (22
→
12 AWG).
Marking
Description
Type
Signals
Activation
CHX
XA
CHX Amplification channel X.
Output
+
-
NA
Figure 23 - Back-up Amplifier Inputs