ISTISJCEBLC200 0.0

Installation Instructions

LC-200/BLC-200

2

3. CONNECTION AND SETUP

Dip 

PULSE

 --> off = 1 pulse - on = 2 pulses

Dip 

RANGE

 --> off = 7m - on = 15m range

Dip 

LED

 --> off = led off - on = led on

Jumpers 

T

 - 

A

 - 

EOL

 open = NC contacts without resistors (not for UL/ULC applications)

Jumpers 

T

 - 

A

 - 

EOL

 closed = DEOL supervision with internal resistors

SUPPLY: power supply 9-15 VDC / 25 mA. 

Note:

 For UL/ULC installations the detector shall be provided with minimum of 4 hours of standby power from either 

a listed compatible control unit or power supply. Use only resistive loads on the outputs.

Installation must be carried out by trained personnel according to professional standards.

The manufacturer accepts no responsibility if the product is tampered with by unauthorized persons. 

The alarm system should be checked for proper operation at least once a month. However, a reliable electronic alarm system does not prevent 

intrusion, robbery, fire or anything else but merely decreases the risk of such situations occurring.

LC-200/BLC-200 complies with requirements EN 50131-2-2 Grade 2, EN 50131-2-2 Class II

Technical Characteristics

RANGE

15 m

HORIZONTAL COVERAGE

100°

LENSES

LODIFF

®

 Fresnel Lens

POLY IR

®

4 material

LED

blue

ALARM DURATION

2 s

SELF-DIAGNOSTICS

-

LED WALK TEST

YES

MICROWAVE FREQUENCY

-

SOLID STATE RELAY

YES

EOL RESISTANCE 

YES

CREEP ZONE DEVICE

YES

CASE TAMPER

YES

BACK TAMPER

YES

ANTI-MASKING

-

PULSE COUNTER

YES

RFI PROTECTION

30 V/m

HEAT COMPENSATION

YES

FULLY DIGITAL

YES

SWIVEL OPTION

YES

POWER SUPPLY

9-15 VDC / 25 mA

COVER MATERIAL

ABS

PET IMMUNITY

YES

OPERATING TEMPERATURE

-10°C to +40°C

UL/ULC tested: 0°C to 49°C

HUMIDITY

93% RH

DIMENSIONS

114 x 63 x 40 mm

LC-200: DEOL supervision

(external resistors/

open jumpers)

NC (no EOL supervision/

open jumpers)

Not used on UL/ULC 

listed installations

101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146

fresnel technologies inc.

2003

SIDE VIEW:

2.1m

(6.8ft)

TOP VIEW:

10m

(33ft)

(50ft)

15m

FRONT VIEW:

(50ft)

15m

5m

(16ft)

jay

WP 0.9 GI 6 T1

PET IMMUNE ARRAY

(28.2ft)

8.6m

(15.7ft)

4.8m

(6.8ft)

2.1m

35.6mm

(1.4 in)

49.8 mm

(1.96 in)

12.5 mm

(0.49 in)

95°

5m

(16ft)

10m

(33ft)

(50ft)

15m

0

Figure 7

101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146

fresnel technologies inc.

2003

SIDE VIEW:

2.1m

(6.8ft)

TOP VIEW:

10m

(33ft)

(50ft)

15m

FRONT VIEW:

(50ft)

15m

5m

(16ft)

jay

WP 0.9 GI 6 T1

PET IMMUNE ARRAY

(28.2ft)

8.6m

(15.7ft)

4.8m

(6.8ft)

2.1m

35.6mm

(1.4 in)

49.8 mm

(1.96 in)

12.5 mm

(0.49 in)

95°

5m

(16ft)

10m

(33ft)

(50ft)

15m

0

Figure 7

Zx COM

+

EOL

A

T

EOL

SUPPLY

ALARM

TAMPER

+

EOL

TAMPER

LC-200

All 3 jumpers open

Negative connected

tamper

5.6 kohm

5.6 kohm

Panel

COM Zx

+

EOL

A

T

EOL

SUPPLY

ALARM

TAMPER

+

EOL

TAMPER

BLC-200

All 3 jumpers open

Negative connected

10 kohm

10 kohm

tamper

Panel

Zx COM

+

EOL

A

T

EOL

SUPPLY

ALARM

TAMPER

+

EOL

TAMPER

LC-200/BLC-200

All 3 jumpers open

Negative connected

tamper

Panel

10m

(33ft)

5m

(16ft)

5m

(16ft)

10m

(33ft)

2.1m

(6.8ft)

2.1m

(6.8ft)

4.8m

(15.7ft)

8.6m

(28.2ft)

15m

(50ft)

SIDE VIEW:

0

DEOL supervision

(internal resistors/closed jumpers)

Zx COM

+

EOL

A

T

EOL

SUPPLY

ALARM

TAMPER

+

EOL

TAMPER

LC-200/BLC-200

COM

R1

R2

NC / NO

TAMPER

All 3 jumpers closed

Zone ok = R1

Zone in alarm = R1 + R2

Tamper zones = open or short circuit

Negative connected

tamper

Panel

LC-200: R1 = 5.6 kohm; R2 = 5.6 kohm

BLC-200: R1 = 5.0 kohm; R2 = 5.0 kohm

BLC-200: DEOL supervision

(external resistors/

open jumpers)