Wiring

Figure 5: Attaching the back housing to the 

trim plate

Figure 4: Attaching the trim plate to the 

junction box

Figure 7: 2-pipe fan coil unit

Figure 8: 4-Pipe fan coil unit

Figure 6: Attaching the front housing to the 

back housing

Summary of Contents for FCP-PA-701-NF

Page 1: ...in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment...

Page 2: ...t protrude 0 07 in to 0 12 in 2 mm to 3 mm 3 Place the top screw hole of the trim plate over the partly inserted screw in the junction box then pull the wires through the trim plate opening 4 Slide th...

Page 3: ...iring Figure 5 Attaching the back housing to the trim plate Figure 4 Attaching the trim plate to the junction box Figure 7 2 pipe fan coil unit Figure 8 4 Pipe fan coil unit Figure 6 Attaching the fro...

Page 4: ...Conventional PTAC Profile Remote sensor Pipe sensor System type 2 pipe FCU with aux heat Available modes 1 Heat only 2 Cool only 3 Heat and cool with auto 4 Heat and cool without auto Pipe state cale...

Page 5: ...ed mode manually HEAT and COOL mode Mode for 5 seconds Table 3 Button combinations Table 2 Preset configuration profiles part 2 of 2 Control mode FCP has four control modes OFF HEAT COOL AUTO The avai...

Page 6: ...configuration settings Press Mode to scroll through the menu and press Up or Down to change options Press Mode to confirm a change Press Back to move backward in the menu or press Mode at the end of...

Page 7: ...location 0 in room 1 in duct 0 26 Remote sensor type 0 type II 1 type III 0 27 Pipe sensor type 0 type II 1 type III 0 28 Pipe state calendar ON OFF OFF 29 Heat to cool day unavailable if pipe state c...

Page 8: ...or Down to set the required period and temperature Repeat this step until you set all the schedule settings 4 Press Mode to save the settings and return to Set Sche menu 5 Press Up or Down to navigate...

Page 9: ...ck if the remote sensor is malfunctioned or damaged Contact technical support ER 07 ERROR_REMOTE_ SENSOR_HI Remote sensor detected a temperature that is too high Verify that the thermostat wiring is c...

Page 10: ...put Set back NC NO dry contact switch Local temperature sensor type NTC temperature sensor accurate to 1 F 0 6 C at 77 F 25 C Remote temperature sensor type NTC temperature sensor accurate to 2 F 1 2...