FCP-PA-701-NF

www.johnsoncontrols.com

Building Technologies & Solutions 

Headquarters: Milwaukee, Wisconsin, USA

 

Branch Offices: Principal Cities World-wide

© Copyright 2021 Johnson Controls.

All specifications and other information shown were current as of document revision and are subject to change without notice.

This product is covered by a limited warranty, details of which can be found at 

www.johnsoncontrols.com/buildingswarranty.

Product warranty

Contact information

Contact your local branch office: 

www.johnsoncontrols.com/locations

Contact Johnson Controls: 

www.johnsoncontrols.com/contact-us

Technical specifications

Specification

Description

Model

FCP-PA-701-NF

Power requirements

20 VAC to 30 VAC, 60 Hz, max. 3 A (3 VA at 24 V nominal)

Output rating

Valve outputs

1 A maximum per each relay channel

(Max. relays ON combination: 1 relay), 20 VAC to 30 VAC

Analog inputs

Remote sensor

10K ohm at 77°F (25°C) NTC sensor

Pipe sensor

10K ohm at 77°F (25°C) NTC sensor

Binary input

Set back

NC/NO dry contact switch

Local temperature sensor type

NTC temperature sensor, accurate to ±1°F (±0.6°C) at 77°F (25°C)

Remote temperature sensor type

NTC temperature sensor, accurate to ±2°F (±1.2°C) at 70°F (21°C)

Wire size 

18 AWG (100 ft [30.5 m] maximum) to 24 AWG (36 ft [11 m] maximum)

Temperature adjustment range

Heat mode

45°F to 90°F (7°C to 32°C)

Cool mode

60°F to 95°F (15°C to 35°C)

Accuracy

Local temperature 

sensor

±1°F (+/-0.6°C)

Remote temperature 

sensor

±2°F (±1.2°C) at 70°F (21°C)

Remote pipe sensor

±5°F (±3.0°C)

Deadband

2°F to 5°F (1°C to 3°C)

Ambient conditions

Operating

14°F to 122°F (-10°C to 50°C); 5% RH to 90% RH, noncondensing

Storage

-4°F to 140°F (-20°C to 60°C); 5% RH to 90% RH, noncondensing

Disconnection means

Type 1B

Pollution degree

2

Rated impulse voltage

330 V

Automatic action

100,000 cycles

Ratings for supply and loading

20 VAC to 30 VAC

Dimensions H x W x D

3.27 in. x 3.94 in. x 0.98 in. (83 mm x 100 mm x 25 mm)

Shipping weight

Product with packing and accessories: 10.1 oz (285 g)
Thermostat only: 4.9 oz (138 g)
Trim plate: 1.2 oz (33 g)

Compliance 

CONFORMS TO UL STD. 60730-1 & 60730-2-9

CERTIFIED TO CSA STD. E60730-1 & E60730-2-9

 

Table 8: 

FCP technical specifications

5013346

Summary of Contents for FCP-PA-701-NF

Page 1: ...in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment...

Page 2: ...t protrude 0 07 in to 0 12 in 2 mm to 3 mm 3 Place the top screw hole of the trim plate over the partly inserted screw in the junction box then pull the wires through the trim plate opening 4 Slide th...

Page 3: ...iring Figure 5 Attaching the back housing to the trim plate Figure 4 Attaching the trim plate to the junction box Figure 7 2 pipe fan coil unit Figure 8 4 Pipe fan coil unit Figure 6 Attaching the fro...

Page 4: ...Conventional PTAC Profile Remote sensor Pipe sensor System type 2 pipe FCU with aux heat Available modes 1 Heat only 2 Cool only 3 Heat and cool with auto 4 Heat and cool without auto Pipe state cale...

Page 5: ...ed mode manually HEAT and COOL mode Mode for 5 seconds Table 3 Button combinations Table 2 Preset configuration profiles part 2 of 2 Control mode FCP has four control modes OFF HEAT COOL AUTO The avai...

Page 6: ...configuration settings Press Mode to scroll through the menu and press Up or Down to change options Press Mode to confirm a change Press Back to move backward in the menu or press Mode at the end of...

Page 7: ...location 0 in room 1 in duct 0 26 Remote sensor type 0 type II 1 type III 0 27 Pipe sensor type 0 type II 1 type III 0 28 Pipe state calendar ON OFF OFF 29 Heat to cool day unavailable if pipe state c...

Page 8: ...or Down to set the required period and temperature Repeat this step until you set all the schedule settings 4 Press Mode to save the settings and return to Set Sche menu 5 Press Up or Down to navigate...

Page 9: ...ck if the remote sensor is malfunctioned or damaged Contact technical support ER 07 ERROR_REMOTE_ SENSOR_HI Remote sensor detected a temperature that is too high Verify that the thermostat wiring is c...

Page 10: ...put Set back NC NO dry contact switch Local temperature sensor type NTC temperature sensor accurate to 1 F 0 6 C at 77 F 25 C Remote temperature sensor type NTC temperature sensor accurate to 2 F 1 2...