Wireless Remote Controller
DRCR
2
No.
Name
Function Description
1
Signal
T
ransmitter
●
Signal transmitter
2
ON/OFF
B
utton
●
Press this button, and the unit will be turned on; press it once more, and the
unit will be turned off. When turning off the unit, the Sleep function will
be canceled, but
preset
time
is still enabled
.
3
MODE
B
utton
●
P
ressing this button, Auto, Cool, Dry, Fan,
and
Heat mode can be selected
sequentially
. Auto mode is
the
default after power
ed
on. Under the Auto
mode,
the setting temperature will not be displayed
.
Under the
Heat
mode, the
initial value is
82°F (
28°C
).
Under other modes, the initial value
is
77°F (
25°
C).
AUTO ; COOL; DRY; FAN; HEAT (only for cooling and heating unit)
4
-
B
utton
●
Preset temperature can be decreased by pressing this button. Pressing
and holding this button for more than
2
seconds
will decrease the preset
temperature rapidly. When the button is released, the setting will be
transmitted.
The temperature adjustment is unavailable under the Auto
mode, but the order can be sent by pressing this button. Centigrade
setting range: 16
°
-
30
°.
Fahrenheit scale setting range
:
61
°
-
86
°
.
+
B
utton
●
Preset temperature can be increased by pressing this button. Pressing and
holding this button for more than
2
seconds
will increase the preset
temperature rapidly. When the button is released, the setting will be
transmitted.
The temperature adjustment is unavailable under the Auto
mode, but the order can be sent by pressing this button. Centigrade
setting range: 16
°
-
30
°;
Fahrenheit scale setting range
:
61
°
-86
°
.
5
FAN
B
utton
●
By pressing this button, Auto, Low, Middle, High speed
selected. After power
ed
on, Auto fan speed is
the
default.
●
AUTO
Low speed
Middle speed
High speed
Note: Under the DRY mode, the fan will be kept running at the low speed
and the fan speed isn't adjustable.
is sequentially