HUMIDIfIeR
Do not mount humidifier in a location where ambient
temperature exceeds 120°f or where freezing temperatures
may occur.
Extreme temperatures may cause the humidifier to leak
which can damage furnishings or structure .
Mount humidifier in a location that allows access for servicing, and
clearance to remove front panel for replacing the canister and side
panel for access to the electrical components during installation .
See
figure 6
for minimum clearances around humidifier .
The humidifier should be mounted as close to the dispersion
tube as possible .
Table 3
shows how capacity is reduced as the
distance between the humidifier and dispersion tube increases . If
the humidifier is mounted on the duct directly below the dispersion
tube, allow space for a bend in the steam hose .
The humidifier can be mounted to a wood surface, or to sheet metal
ductwork if it is structurally stable . Do not mount humidifier to fiber
duct board .
The humidifier must be mounted to a vertical surface and must be
mounted level in the upright position .
16" for
Steam
Hose
30" for
Service
Access
16" for
Electrical
Access
4"
16"
for Drain
FRONT VIEW
SIDE VIEW
fIGURe 6 – Clearances
90-1702
InSTallaTIon InSTRUCTIonS
(ConTInUeD)
fIGURe 5
90-1705
Steam Hose
Dispersion Tube
Steam Hose
1-1/2" Hose Clamp
1-1/2" Hose Clamp
1" Copper Pipe
3/4" x 1" Reducing Coupling
Humidifier