background image

– 5 –

Relief Valve Requirements (T&P)

All water heaters must be fitted with a proper temperature
and pressure relief valve. These valves must be certified as
meeting the requirements of the “

Standard For Relief

Valves For Hot Water Supply Systems, ANSI Z21.22/CSA
4.4”

.

If this water heater has been exposed to flooding, freezing,
fire or any unusual condition, do not put it into operation until
it has been inspected and approved by a qualified service
technician.

THESE CONDITIONS CAN RESULT IN UNSEEN INTER-
NAL DAMAGE

and are not subject to warranty coverage.

This product contains fiberglass wool and ceramic fiber
materials. Airborne fibers from these materials have been
listed by the State of California as a possible cause of can-
cer through inhalation. Use special care when handling
ceramic fiber (chamber lining and base insulation) materials.
Ceramic fibers can be converted to chrystobalites, a sub-
stance listed as a probable cause of cancer. Suppliers of
fiberglass wool products recommend the following mea-
sures be taken when handling these materials:

Precautionary measures:

Avoid breathing fiberglass dust.

Avoid contact with skin and eyes.

Use a National Institute for Occupational Safety and
Health (NIOSH) approved dust/mist respirator.

Wear long-sleeved, loose fitting clothing, gloves and eye
protection.

Wash work clothes separately from other clothing. Rinse
washer thoroughly.

Removing the burner may generate airborne fiber concen-
tration requiring additional protection.
First aid measures:

Eye contact - Flush eyes with sterile water to remove for-
eign objects. If irritation or other symptoms persist, seek
medical attention.

Skin contact - Wash affected areas gently with soap and
warm water after handling.

Fuel Specifications

All JOHN WOOD brand water heaters are designed to burn
only fuels not heavier than No.2 (furnace) oil.

III) INSTALLATION

Unpacking the Water Heater

Important:

Do not remove any permanent instructions,

labels, or the data label from outside of the water heater or
on the inside of panels.

Remove exterior packaging and place installation com-
ponents aside.

Inspect all parts for damage prior to installation and
start-up.

Completely read all instructions before attempting to
assemble and install this product.

If you observe damage to the water heater or any of its com-
ponents, DO NOT ASSEMBLE OR INSTALL IT OR MAKE
ANY ATTEMPT TO FIX THE DAMAGED PART(S). Contact
the place of purchase for further instructions.

After installation, dispose of packaging material in the
proper manner.

CAUTION:

Possible cancer hazard by inhalation. Can
cause respiratory, skin and eye irritation.

WARNING

• Do not use gasoline, crank case oil or an

oil containing gasoline.

• Do not tamper with unit or controls.
• Do not leave paper or rags around the

burner or heater.

• Do not experiment with the burner.

CAUTION

Hydrogen gas can be produced in a hot water system
served by this heater that has not been used for a long
period of time (generally two (2) weeks or more).

Hydrogen gas is extremely flammable and can ignite
when exposed to a spark or flame.

To reduce the risk of

injury under these conditions, it is recommended that the
hot water faucet be opened for several minutes at the
kitchen sink before using any electrical appliance con-
nected to the hot water system. Use caution in opening
faucets. If hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to flow. There should be no smoking or
open flame near the faucet at the time it is open.

WARNING

Excessive Weight Hazard

Use two or more people to move and install
water heater. Failure to do so can result in
back or other injury.

Summary of Contents for JW317

Page 1: ...mmable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified Oil Burner Technician or your oil supplier Immediately call your oi...

Page 2: ...g Installation of Power Venter Water Supply 11 Piping Installation Filling the Water Heater Closed System Thermal Expansion Temperature and Pressure T P Relief Valve The Temperature and Pressure Relie...

Page 3: ...se instructions An identifying data plate can be found at the front of your water heater When referring to your water heater always have the information listed on the data plate readily available Prot...

Page 4: ...ater igniter or burner flame can ignite these vapours causing a flashback fire or explosion which may result in severe property damage serious personal injury or death If flammable liquids or vapours...

Page 5: ...ications All JOHN WOOD brand water heaters are designed to burn only fuels not heavier than No 2 furnace oil III INSTALLATION Unpacking the Water Heater Important Do not remove any permanent instructi...

Page 6: ...r an anti siphon device must be used to prevent flow of oil in case of an oil line break Support the oil lines as required by applic able codes Make tank connections with swing joints or cop per tubin...

Page 7: ...n mm in mm in mm in mm in mm in mm in JWF307 508 20 X 152 6 610 24 51 2 51 2 457 18 229 9 JWF507 559 22 X 152 6 610 24 51 2 51 2 457 18 229 9 JWF657 660 26 X 152 6 610 24 51 2 51 2 406 16 152 6 JWF307...

Page 8: ...4 826 in 23 1 3 23 32 1 2 mm 1241 1372 1486 in 48 7 8 54 58 1 2 mm 150 178 178 in 6 7 7 G H C D E F Model Diam A B A B C D E F G H JWF307 JWF507 JWF657 JWF307V mm 508 559 660 508 in 20 22 26 20 mm 229...

Page 9: ...appliance or for replacing the air vented by other exhaust devices within the house Outdoor Combustion Ventilation Air Unconfined space If the water heater is installed in an unconfined space in a bui...

Page 10: ...e to do any of the following can result in serious property damage severe bodily injury or death Clean the chimney including removal of blockage Repair or replace damaged pipe or liner Repair mortar a...

Page 11: ...ost Purge Installation of Power Venter The Installation Code for Oil Burning Equipment CSA B139 04 or Standard for the Installation of Oil Burning Equipment NFPA 31 local codes and the man ufactures i...

Page 12: ...l hot water faucets served by the system to allow air to escape from the tank 3 Open the cold water inlet valve NOTE When filling avoid water leakage Do not allow the insulation of the water heater to...

Page 13: ...nd pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater The valve s relief pressure must not exceed the work...

Page 14: ...llations must comply with the latest editions of these codes Canadian Electrical Code Part 1 CSA C22 1 Canada National Electrical Code ANSI NFPA 70 USA Any additional local provincial national or stat...

Page 15: ...VE BURNER MOTOR IGNITOR LIMIT JUMPER CAD CELL T T F F WHITE BLACK 48245 BURNER JUNCTION BOX L2 NEUTRAL Figure 11 Typical Primary Control Wiring 48245 BLOCKED VENT SAFETY SWITCH L1 HOT ORANGE GROUND JU...

Page 16: ...f the tank Check Here 1 Have the safety precautions described in the manual been implemented 2 Does the oil piping conform to the recommen dations of your Oil Supply Company 3 Has the oil piping been...

Page 17: ...upply and open a nearby hot water faucet to depressurize the water tank 3 Drain approximately 20 litres 5 US gallons of water from tank Refer to Draining and Flushing for proper procedures Close drain...

Page 18: ...bustion air to the heater Keep the appliance area clear and free from combustible material gasoline and other flammable vapors and liq uids Keep the air ventilation openings unobstructed If dust and l...

Page 19: ...er in it Re Starting The Heater After Shut Down 1 Follow instructions for Filling the Water Heater and Startup when heater is ready to be put back into ser vice 2 If the heater does not start check to...

Page 20: ...mands for both domestic service hot water and space heating requirement The sizing and installation must be per formed in accordance with good engineering practice such as ASHRAE Handbooks HRAI Hydron...

Page 21: ...open position and must be connected to the water pump WATER HEATER 200mm TO 300mm 8 in TO 12 in HOT OUTLET EXPANSION TANK OPTIONAL MIXING VALVE COLD INLET CHECK VALVE IF USED REQUIRES EXPANSION TANK...

Page 22: ...GPH BECKETT AFG GSW J7037 1 0 GPH U S ONLY BECKETT AFG GSW J7036 1 0 GPH MASS ONLY CARLIN EZ197397AJW717 1 0 GPH CARLIN 97397AJW717 1 00 x 60A DEL 38018 100 psi 9 AERO FAFC 2X 0 65 0 75 GPH AERO SV 2...

Page 23: ...0 75 GPH BECKETT AFG GSW J5999 0 75 GPH CARLIN EZ196983AJW507 0 75 GPH CARLIN 96983AJW507 0 75 x 60A DEL 85472 100 psi 7 RIELLO R35 3 05 OR 0 65 GPH RIELLO R35 3 05 OR 0 65 x 60A CT Delavan 160 0 75 5...

Page 24: ...the water heater s Model Number SKU Serial Number date of purchase and date of installation c THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THIS EXPRESS WARRANTY IS W...

Page 25: ...gency beyond the control of the Manufacturer or s The water heater is installed in a closed system without adequate provision for thermal expansion 3 Except when speci cally prohibited by the applicab...

Page 26: ...26 This page intentionally left blank May be used for notes or to record other installation information...