b.  The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) 

and/or regulations or, in their absence, with the latest edition of the Natural Gas and Propane Installation Code, 
and/or the Canadian Electrical Code; or

 

c.  The water heater is not installed, operated, and maintained in accordance with the Manufacturer’s instructions, 

including if the water heater has any additional aftermarket equipment introduced into the sealed system not ap-
proved by the Manufacturer; or

 

d.  The water heater or any of its component parts are damaged or fails from operation with an empty or partially empty 

tank (such as, but not limited to elements burned out in a dry tank); or

 

e.  The water heater or any part has been under water; or

 

f.  The water heater is exposed to highly corrosive atmospheric conditions. No warranty extends, for example, and 

without limitation of the foregoing, to Units exposed to: salts, chemicals, exhausts, pollutants, or contaminants; or

 

g.  The water heater is not continuously supplied with potable water; or

 

h.  The water heater replacement is requested for reasons of noise, taste, odour, discolouration, and/or rust; or

 

i.  The water heater is operated at temperatures exceeding the maximum setting of the thermostat and/or high limit 

control provided by the Manufacturer, or at water pressures exceeding the pressure reading stated on the Unit; or

 

j.  The water heater is operated without an operating anode; or

 

k.  The water heater is supplied or operated with deionized water; or

 

l.  The water heater is removed from its original installation location; or

 

m. The water heater is installed outdoors (this water heater is intended only for indoor installation); or

 

n.  The water heater is converted, or is attempted to be converted, from one voltage or wattage to another, if an electric 

water heater, or from one gas type to another, if a gas water heater; or

 

o.  The water heater has not been fi red at the factory rated input and fuel for which it was factory built; or

 

p.  The water heater or any of its component parts fail due to sediment build-up; or

 

q.  The water heater does not have installed a properly operating temperature and pressure relief valve, certifi ed to 

ANSI Z21.22/CSA “Requirements for Relief Valves for Hot Water Supply Systems”; or 

 

r.  The water heater or any of its component parts fail because of fi re, fl oods, lightning, or any other act of God, or any 

other contingency beyond the control of the Manufacturer; or

 

s.  The water heater is installed in a closed system without adequate provision for thermal expansion.

 

3. Except when specifi cally prohibited by the applicable law, the Owner, and not the Manufacturer, shall be liable for 

and shall pay for all charges for labour or other expenses incurred in the removal, repair, or replacement of the water 
heater or any component part(s) claimed to be defective or any expense incurred to remedy any defect in the product. 
Such charges may include, but are not necessarily limited to:

 

a.  All freight, shipping, handling, and delivery costs of forwarding a new water heater or replacement part(s) to the 

Owner.

 

b.  All costs necessary or incidental in removing the defective water heater or component part(s) and installing a new 

water heater or component part(s).

 

c.  Any material required to complete and/or permits required for the installation of a new water heater or replacement 

part(s), and

 

d.  All costs necessary or incidental in returning the defective water heater or component part(s) to a location desig-

nated by the Manufacturer.

 

4.  The terms of this Limited Warranty cannot be modifi ed by any person, whether or not he/she claims to represent or 

act on behalf of the Manufacturer.

E.  HOW THE ORIGINAL OWNER CAN MAKE A WARRANTY CLAIM.
 

1. The Owner should submit the warranty claim direct to the Manufacturer’s Service Department, at the address or phone 

number listed below, and the Manufacturer will arrange for the handling of the claim.

 

2. Whenever any inquiry or request is made, be sure to include the water heater’s Catalogue Number, Model Number, 

Serial Number, date of purchase, date of installation, and location of installation.

This Warranty and the Manufacturer’s obligations shall be construed and determined in accordance with the laws of both the 
Province of Ontario, and of Canada in force therein. This Warranty does not affect specifi c legal rights of a consumer under 
applicable law, except to the extent that such rights may be waived or replaced, and the provisions hereof are deemed to be 
amended to the extent necessary. The unenforceability of any provision, in whole or in part, of this Certifi cate shall not affect 
the remaining provisions. Any and all repair and/or replacement of part(s) or Unit are the sole and exclusive remedy avail-
able against the Manufacturer.

John Wood Water Heaters

599 Hill Street West

Fergus, ON Canada N1M 2X1

Should you have any questions, please

Visit us online at 

www.johnwoodwaterheaters.com

, or

E-mail us at [email protected], or

Call our Technical Support line at 1 888 GSW TECH (479 8324)

Summary of Contents for JW317

Page 1: ...mmable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified Oil Burner Technician or your oil supplier Immediately call your oi...

Page 2: ...g Installation of Power Venter Water Supply 11 Piping Installation Filling the Water Heater Closed System Thermal Expansion Temperature and Pressure T P Relief Valve The Temperature and Pressure Relie...

Page 3: ...se instructions An identifying data plate can be found at the front of your water heater When referring to your water heater always have the information listed on the data plate readily available Prot...

Page 4: ...ater igniter or burner flame can ignite these vapours causing a flashback fire or explosion which may result in severe property damage serious personal injury or death If flammable liquids or vapours...

Page 5: ...ications All JOHN WOOD brand water heaters are designed to burn only fuels not heavier than No 2 furnace oil III INSTALLATION Unpacking the Water Heater Important Do not remove any permanent instructi...

Page 6: ...r an anti siphon device must be used to prevent flow of oil in case of an oil line break Support the oil lines as required by applic able codes Make tank connections with swing joints or cop per tubin...

Page 7: ...n mm in mm in mm in mm in mm in mm in JWF307 508 20 X 152 6 610 24 51 2 51 2 457 18 229 9 JWF507 559 22 X 152 6 610 24 51 2 51 2 457 18 229 9 JWF657 660 26 X 152 6 610 24 51 2 51 2 406 16 152 6 JWF307...

Page 8: ...4 826 in 23 1 3 23 32 1 2 mm 1241 1372 1486 in 48 7 8 54 58 1 2 mm 150 178 178 in 6 7 7 G H C D E F Model Diam A B A B C D E F G H JWF307 JWF507 JWF657 JWF307V mm 508 559 660 508 in 20 22 26 20 mm 229...

Page 9: ...appliance or for replacing the air vented by other exhaust devices within the house Outdoor Combustion Ventilation Air Unconfined space If the water heater is installed in an unconfined space in a bui...

Page 10: ...e to do any of the following can result in serious property damage severe bodily injury or death Clean the chimney including removal of blockage Repair or replace damaged pipe or liner Repair mortar a...

Page 11: ...ost Purge Installation of Power Venter The Installation Code for Oil Burning Equipment CSA B139 04 or Standard for the Installation of Oil Burning Equipment NFPA 31 local codes and the man ufactures i...

Page 12: ...l hot water faucets served by the system to allow air to escape from the tank 3 Open the cold water inlet valve NOTE When filling avoid water leakage Do not allow the insulation of the water heater to...

Page 13: ...nd pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater The valve s relief pressure must not exceed the work...

Page 14: ...llations must comply with the latest editions of these codes Canadian Electrical Code Part 1 CSA C22 1 Canada National Electrical Code ANSI NFPA 70 USA Any additional local provincial national or stat...

Page 15: ...VE BURNER MOTOR IGNITOR LIMIT JUMPER CAD CELL T T F F WHITE BLACK 48245 BURNER JUNCTION BOX L2 NEUTRAL Figure 11 Typical Primary Control Wiring 48245 BLOCKED VENT SAFETY SWITCH L1 HOT ORANGE GROUND JU...

Page 16: ...f the tank Check Here 1 Have the safety precautions described in the manual been implemented 2 Does the oil piping conform to the recommen dations of your Oil Supply Company 3 Has the oil piping been...

Page 17: ...upply and open a nearby hot water faucet to depressurize the water tank 3 Drain approximately 20 litres 5 US gallons of water from tank Refer to Draining and Flushing for proper procedures Close drain...

Page 18: ...bustion air to the heater Keep the appliance area clear and free from combustible material gasoline and other flammable vapors and liq uids Keep the air ventilation openings unobstructed If dust and l...

Page 19: ...er in it Re Starting The Heater After Shut Down 1 Follow instructions for Filling the Water Heater and Startup when heater is ready to be put back into ser vice 2 If the heater does not start check to...

Page 20: ...mands for both domestic service hot water and space heating requirement The sizing and installation must be per formed in accordance with good engineering practice such as ASHRAE Handbooks HRAI Hydron...

Page 21: ...open position and must be connected to the water pump WATER HEATER 200mm TO 300mm 8 in TO 12 in HOT OUTLET EXPANSION TANK OPTIONAL MIXING VALVE COLD INLET CHECK VALVE IF USED REQUIRES EXPANSION TANK...

Page 22: ...GPH BECKETT AFG GSW J7037 1 0 GPH U S ONLY BECKETT AFG GSW J7036 1 0 GPH MASS ONLY CARLIN EZ197397AJW717 1 0 GPH CARLIN 97397AJW717 1 00 x 60A DEL 38018 100 psi 9 AERO FAFC 2X 0 65 0 75 GPH AERO SV 2...

Page 23: ...0 75 GPH BECKETT AFG GSW J5999 0 75 GPH CARLIN EZ196983AJW507 0 75 GPH CARLIN 96983AJW507 0 75 x 60A DEL 85472 100 psi 7 RIELLO R35 3 05 OR 0 65 GPH RIELLO R35 3 05 OR 0 65 x 60A CT Delavan 160 0 75 5...

Page 24: ...the water heater s Model Number SKU Serial Number date of purchase and date of installation c THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THIS EXPRESS WARRANTY IS W...

Page 25: ...gency beyond the control of the Manufacturer or s The water heater is installed in a closed system without adequate provision for thermal expansion 3 Except when speci cally prohibited by the applicab...

Page 26: ...26 This page intentionally left blank May be used for notes or to record other installation information...

Reviews: