11
STORAGE CAPACITIES
TABLE 2
MODEL
U. S. GALLONS
LITERS
(A)JWSH100150
100
379
(A)JWSH100199
100
379
(A)JWSH100250
100
379
GAS LINE CONNECTION SIZE
TABLE 1
† MODEL
SERIES
NATURAL GAS
PROPANE GAS
(A)JWSH100150
200/201
3/4 "NPT
3/4 "NPT
(A)JWSH100199
200/201
3/4 "NPT
3/4 "NPT
(A)JWSH100250
200/201
3/4 "NPT
3/4 "NPT
† Depending on the installed equivalent length, and/or the number of appliances connected, the
supply gas line size may have to be increased beyond the minimum required sizes - see Gas
Line Sizing on page 39.
8. Locate the water heater where an adequate supply of fresh
air for combustion and ventilation can be obtained. See Air
Requirements on page 17.
9. Locate the water heater where the vent and intake air piping,
when installed, will remain within the maximum equivalent
lengths allowed. See Venting Requirements on page 21.
10. Do not locate the water heater where noise (such as
the Combustion Blower) during normal operation will be
objectionable in adjacent areas.
11. Do not locate the water heater where the subsequent
installation of the vent (exhaust) or intake air terminations
would be objectionable due to noise at the termination(s).
This includes locations close to or across from windows and
doors. See Venting Installation on page 20.
Fire or Explosion Hazard
Read instruction manual before
installing, using or servicing
water heater.
Avoid all ignition sources if you smell gas.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Use only the gas shown on the water heater rating label.
Keep ignition sources away from faucets after extended
periods of non-use.
Maintain required clearances to combustibles.
Do not expose water heater controls to excessive gas
pressure.
LOCATING THE WATER HEATER
Carefully choose a location for the new water heater. The
placement is a very important consideration for the safety of the
occupants in the building and for the most economical use of the
water heater.
Property Damage Hazard
All water heaters eventually leak.
•
Do not install without adequate drainage.
•
CAUTION
Whether replacing an existing water heater or installing the water
heater in a new location observe the following critical points:
1. The water heater must be located indoors.
2. The water heater must not be located in an area where it will
be subject to freezing temperatures.
3. Locate the water heater so it is protected and not subject to
physical damage by a moving vehicle.
4. Locate the water heater on a level surface.
5. Locate the water heater near a floor drain. The water heater should
be located in an area where leakage of the tank or connections
will not result in damage to the area adjacent to the water heater
or to lower floors of the structure. When such locations cannot be
avoided, it is recommended that a metal drain pan, adequately
drained, be installed under the water heater.
6. Locate the water heater close to the point of major hot water usage.
7. Locate the water heater close to a 120 VAC power supply.
See Power Supply on page 13 for requirements.
GAS PRESSURE REQUIREMENTS
TABLE 3
MODEL
MANIFOLD PRESSURE
MINIMUM SUPPLY PRESSURE
MAXIMUM SUPPLY PRESSURE
NATURAL GAS
PROPANE GAS
NATURAL GAS
PROPANE GAS
NATURAL GAS
PROPANE GAS
(A)JWSH100150
0" W.C. (0 kPa)
0" W.C. (0 kPa)
4.4” W. C. (1.10 kPa)
8.5” W. C. (2.12 kPa)
14” W. C. (3.49 kPa)
14” W. C. (3.49 kPa)
(A)JWSH100199
0” W. C. (0 kPa)
0” W. C. (0 kPa)
4.4” W. C. (1.10 kPa)
8.5” W. C. (2.12 kPa)
14” W. C. (3.49 kPa
14” W. C. (3.49 kPa)
(A)JWSH100250
0” W. C. (0 kPa)
0” W. C. (0 kPa)
4.4” W. C. (1.10 kPa)
8.5” W. C. (2.12 kPa)
14” W. C. (3.49 kPa)
14” W. C. (3.49 kPa)
RECOVERY CAPACITIES
TABLE 4
U. S. GALLONS/HR & LITERS/HR AT TEMPERATURE RISE INDICATED
Model
Type of
Gas
Input
Thermal
Efficiency%
°F
30°F
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
Btu/hr
kW
°C
17°C
22°C
28°C
33°C
39°C
44°C
50°C
56°C
61°C
67°C
72°C
78°C
(A)JWSH100150
Natural
150,000
44
98
GPH
594
445
356
297
255
223
198
178
162
148
137
127
Propane
LPH
2248
1686
1349
1124
963
843
749
674
613
562
519
482
(A)JWSH100199
Natural
199,900
58
97
GPH
783
588
470
392
336
294
261
235
214
196
181
168
Propane
LPH
2965
2224
1779
1483
1271
1112
988
890
809
741
684
635
(A)JWSH100250
Natural
250,000
73
96
GPH
970
727
582
485
416
364
323
291
264
242
224
208
Propane
LPH
3670
2753
2202
1835
1573
1376
1223
1101
1001
918
847
786