background image

VALVES

P

ART

N

O

.

S

IZE MM

15 ESOT

15

P

ART

N

O

.

S

IZE

15 APT

15mm x 3/4" BSP

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.
For torque figures on plastic threads 

please see Technical Checklist.

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

P

ART

N

O

.

S

IZE MM

15STV

15

22STV

22

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

P

ART

N

O

.

S

IZE MM

15SV

15

22SV

22

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

P

ART

N

O

.

S

IZE MM

15BDC

15

P

ART

N

O

.

S

IZE MM

15DCV

15

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

P

ART

N

O

.

S

IZE MM

10HSV

10

15HSV

15

22HSV

22

Suitable for central heating systems.

Suitable for central heating systems.
Manufactured in DZR Brass.
Please note a collet cover cannot be used on 

a Speedfit end assembled with a draincock.
Draincocks can be fitted with a standard 

fitting fitted with a collet clip.
When using with Twist and Lock Fittings 

the fitting must be locked.

P

ART

N

O

.

S

IZE

15PTSV

15 x 1/2”

22PTSV

22 x 3/4”

Suitable for central heating systems.

P

ART

N

O

.

S

IZE MM

15HSV-BRASS

15

Suitable for central heating systems.

PIPE AND PIPE ACCESSORIES

P

ART

N

O

.

S

IZE MM

CM1810S

10

CM1815S

15

CM1822S

22

CM1810W

10

CM1815W

15

CM1822W

22

CM1810R

10

CM1815R

15

CM1822R

22

CM1810B

10

CM1815B

15

CM1822B

22

Suitable for central heating systems.

White and grey collet clips prevent accidental 

release of pipe from standard fittings.
Red and blue clips provide colour coding of pipe,

they should not be used to prevent accidental 

release of pipe.

P

ART

N

O

.

S

IZE MM

PKM1910W

10

PKM1910R

10

PKM1910B

10

AM1915W

15

PM1915R

15

PM1915B

15

AM1922W

22

PM1922R

22

PM1922B

22

Available in white, red or blue

Suitable for central heating systems

P

ART

N

O

.

S

IZE

15BPEX-20x2L

15mm x 2m

15BPEX-20x3L

15mm x 3m

15BPEX-20x6L

15mm x 6m

22BPEX-20x2L

22mm x 2m

22BPEX-20x3L

22mm x 3m

22BPEX-20x6L

22mm x 6m

28BPEX-10x3L

28mm x 3m

28BPEX-10x6L

28mm x 6m

Suitable for central heating systems.

Straight lengths

The pipe has an inner barrier to 
stop the ingress of atmosphere.

*By special order only.

P

ART

N

O

.

S

IZE MM

TSM10N

10

TSM15N

15

TSM22N

22

TSM28N

28

Suitable for central heating systems.

To be used when connecting Speedfit Pipe
to a compression fitting. 
See Page 16.

P

ART

N

O

.

S

IZE

10BPEX-25C

10mm x 25m

10BPEX-50C

10mm x 50m

10BPEX-100C

10mm x 100m

15BPEX-25C

15mm x 25m

15BPEX-50C

15mm x 50m

15BPEX-100C

15mm x 100m

15BPEX-120C

15mm x 120m

15BPEX-150C

15mm x 150m

22BPEX-25C

22mm x 25m

22BPEX-50C

22mm x 50m

Suitable for central heating systems.

Coils

The pipe has an inner barrier to 
stop the ingress of atmosphere.

British Gas accepted for water 
pipe in vented and sealed central
heating systems.

P

ART

N

O

.

S

IZE MM

STS10

10

STS15

15

STS22

22

STS28

28

Suitable for central heating systems.

To be used only when connecting 
Speedfit Pipe and Speedfit Fittings 
to enhance the sealing security of 
the connections. See page 05.

P

ART

N

O

.    

S

IZE

BLACK
15BLK CON-25C

15mm x 25m

15BLK CON-50C

15mm x 50m

22BLK CON-25C

22mm x 25m

22BLK CON-50C

22mm x 50m

RED
15RED CON-50C

15mm x 50m

22RED CON-50C

22mm x 50m

BLUE
15BLU CON-50C

15mm x 50m

22BLU CON-50C

22mm x 50m

To be used when Speedfit Pipe is laid 
in Concrete and Masonry, see section 
on page 20.

*

P

ART

N

O

.    

S

IZE

CONELB

FITS 10, 15 & 22mm

STOP VALVE

WASHING MACHINE TAP

EMERGENCY SHUT OFF TAP

DOUBLE CHECK VALVE

PLASTIC SERVICE VALVE

BRASS SERVICE VALVE

BRASS CHROME PLATED SERVICE VALVE

BRASS CHROME PLATED SERVICE VALVE
WITH TAP CONNECTOR

BRASS DRAIN COCK

PEX BARRIER PIPE

PEX BARRIER PIPE

SUPERSEAL PIPE INSERT

PIPE INSERT

CONDUIT PIPE

CONDUIT ELBOW

COLLET COVER

COLLET LOCKING CLIP

P

ART

N

O

.

S

IZE MM

15BSC

15

Only suitable for central heating.
Head and Body manufactured in DZR Brass.

BRASS STOP TAP

13

14

Grey

P

ART

N

O

.

S

IZE MM

10BV

10

15BV

15

22BV

22

Suitable for central heating systems.

BRASS CHROME PLATED BALL VALVE

White

Red

Blue

P

ART

N

O

.

S

IZE

15BPB-25C

15mm x 25m

15BPB-50C

15mm x 50m

15BPB-100C

15mm x 100m

15BPB-120C

15mm x 120m

15BPB-150C

15mm x 150m

22BPB-25C

22mm x 25m

22BPB-50C

22mm x 50m

Suitable for central heating systems.

Coils

The pipe has an inner barrier to 
stop the ingress of atmosphere.

British Gas accepted for water 
pipe in vented and sealed central
heating systems.

POLYBUTYLENE BARRIER PIPE

Each Valve has a red and a blue indice.

P

ART

N

O

.

S

IZE

15SVSTC

15 x 1/2”

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

PLASTIC SERVICE VALVE WITH TAP CONNECTOR

P

ART

N

O

.

S

IZE

15SVBTC

15 x 1/2”

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

PLASTIC ANGLE SERVICE VALVE 
WITH TAP CONNECTOR

P

ART

N

O

.    

S

IZE

15PIP-50C-E

15mm x 50m

22PIP-50C-E

22mm x 50m

PIPE IN PIPE

P

ART

N

O

.

S

IZE MM

PLASTIC BALL VALVE

Not suitable for central heating systems.
Each Valve has a red and a blue indice.

15SV-H

15

22SV-H

22

Grey

White

Grey

White

P

ART

N

O

.

S

IZE

15SVSTC-W

15 x 1/2”

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

P

ART

N

O

.

S

IZE

15SVBTC-W

15 x 1/2”

Not suitable for central heating systems.

Hot and Cold water only, 65°C maximum.

Summary of Contents for Speedfit

Page 1: ...rposes only Subject to our Terms and Conditions of Sale available on request Z2105 217 10 07 No s 95 3177 BS7291 KM39767 AVAILABLE FROM THE PUSH FIT SOLUTION FOR PLUMBING HEATING SYSTEMS UK PRODUCT RA...

Page 2: ...ducts A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development 01 02 Technical Support Our national team of Technical...

Page 3: ...s application Speedfit fittings suitable for central heating systems can withstand temperatures up to 114 C intermittently for short periods Speedfit fittings shown as not suitable for central heating...

Page 4: ...ead The O ring on the Superseal Pipe Insert provides a secondary seal against the bore of the fitting A good connection has been made Gap between Cap and Flange Pipe mark indicates full insertion Twis...

Page 5: ...e connectors are useful when replacing existing brassware or in other confined spaces Coupling up to a supply is easy The pipe is simply pushed home into the Speedfit connection and is instantly secur...

Page 6: ...28 x 22 PEMSTC1514 15mm x 1 2 BSP PEMSTC1516 15mm x 3 4 BSP PEMSTC2216 22mm x 3 4 BSP PEMBTC1514 15mm x 1 2 BSP PART NO SIZE MM PSE4610W 10 PSE4615W 15 PSE4622W 22 Suitable for central heating systems...

Page 7: ...50mm long 1000mm long PART NO SIZE MM X MALE FLX48 12 x M10 FLX28 15 x M10 FLX29 15 x M12 FOR MONOBLOC MIXERS PART NO SIZE MM X BSP PART NO SIZE MM X BSP FLX36P 15 x 1 2 ELBOW PATTERN 300mm long 300mm...

Page 8: ...15BPEX 120C 15mm x 120m 15BPEX 150C 15mm x 150m 22BPEX 25C 22mm x 25m 22BPEX 50C 22mm x 50m Suitable for central heating systems Coils The pipe has an inner barrier to stop the ingress of atmosphere...

Page 9: ...Copper pipe PE copper coupler MDPE pipe with Pipe Insert Collet clip Speedfit Pipe Speedfit pipe should never be connected directly to a boiler Although most modern boilers have a high limit thermost...

Page 10: ...M M M M M M P P Plastic M Metal NB All Waste Pipes are plastic 1 Supplementary bonding is carried out to the earth terminal of protective conductors of class I and class II equipment within the bathro...

Page 11: ...rs does not affect the fire resistant properties of the structure Speedfit pipework can be easily cabled through studwork and within wall systems as well as behind dot and dab plasterboard installatio...

Page 12: ...ntrolled by one or more thermostats which signal the Pump Pack when heat is required 21 22 RADIATOR SYSTEM AND HEAT GRADIENT UNDERFLOOR HEATING SYSTEM An Underfloor Heating System heats mainly by radi...

Page 13: ...ntralised control of the set back functions for the whole manifold via a digital programmer The timer acts as a timed switch to alternate between daytime and Set Back time PART DESCRIPTION PACK NO QTY...

Page 14: ...on of the outside walls and windows will determine the pattern of the pipe layout The counterflow pattern is recommended although other options are shown below Single Serpentine Double Serpentine Trip...

Page 15: ...nst the face of fitting With the collet held in this position the pipe can be withdrawn We recommend the replacement of the O ring and collet before making a new connection Remove collet cover pull ou...

Page 16: ...ulose based paints paint thinners or strippers solder flux or acid based descalents or aggressive household cleaning products Exposure to sunlight Speedfit products when used indoors are not affected...

Reviews: