background image

SPEEDFIT SYSTEM COMPONENTS

Speedfit  Underfloor  Heating  Products  have  been  designed
and  are  manufactured  to  European  and  UK  Standards,
including ISO 9001 and DIN4726.

Speedfit  Manifolds  are  manufactured  from  high  quality
DZR brass to the highest UK and European standards.

A unique feature is that connections to the heating pipes
are Speedfit Push Fit, offering much reduced installation
time. Flow and return rails are offset and the angles can
be altered, all making for an easy installation.

The  manifolds  are  complete  with  adjustable  flow  gauge,
drain  valve  and  air  bleed  valve.  They  are  pre  assembled
on wall brackets and supplied with screws and plugs. 

Manufactured  in  DZR  brass,  the  pack
consists  of  a  pump,  mixing  valve  and
overheat temperature thermostat.

Offered in PEX or Polybutylene, Speedfit Pipe has an 
inner  barrier  to  prevent  the  ingress  of  atmosphere,  it  is
manufactured  and  Kitemarked  to  British  Standard 
BS7291 : Parts 1,2 & 3: Class S. 

It is lightweight and flexible making it especially suitable
for underfloor heating installations.

For  screed  systems,  the  pipe  is  attached  directly  to
insulation with staples, floor clips or mounting rails.

Spreader  Plates  are  available  for  timber  flooring  using
either traditional joists or TJI Joists. 

A  mains  operated  room  thermostat.  The  temperature  is  set
manually  for  ‘daytime’  temperature.  A  ‘set  back’  mode,
reducing the temperature by 4

o

C, is controlled by a Centralised

or  Remote  System  Timer.  The  Thermostat  has  a  manual
override  for  permanent  ‘Daytime’  or  permanent  ‘Set  back’
temperature  and  can  be  used  in  conjuncton  with  a  Wet  Area
Probe.

Speedfit  offer  several  ways  of  securing  pipe  to  the
insulation layer in a screeded floor.

23

24

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHMAN4

4 ZONE MANIFOLD

1

JGUFHMAN6

6 ZONE MANIFOLD 

1

JGUFHMAN8

8 ZONE MANIFOLD 

1

JGUFHMAN10

10 ZONE MANIFOLD

1

JGUFHMAN12

12 ZONE MANIFOLD

1

MANIFOLDS

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGPUMPPACK

PUMP PACK

1

PUMP PACK

Hot water is taken from the boiler, mixed to the required
temperature  and  circulated  via  the  manifold  to  the 
heating circuits, the temperature and volume of water is
constantly  altered  to  maintain  the  requirements  of  the
system.  Flow  temperature  can  be  altered  by  turning  the
hand wheel on the mixing valve unit. 

The  pack  is  light  and  compact  so  a  wall  bracket  is  not
needed and flat face unions make for an easy connection
to the manifold. 

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHA(240 v) 240 v CIRCUIT ACTUATOR VALVE

1

ACTUATOR VALVE

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFH4ZM

MASTER WIRING CENTRE 4 ZONE

1

MASTER WIRING CENTRE

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHTH

ROOM THERMOSTAT WITH

1

SET BACK TEMPERATURE REDUCTION MODE

ROOM THERMOSTAT

P

ART

D

ESCRIPTION

S

IZE

P

ACK

N

O

.

Q

TY

15BPEX-50C

BARRIER PIPE 

15MM X 50M 

1

15BPEX-100C BARRIER PIPE  15MM X 100M  1
15BPEX-120C BARRIER PIPE  15MM X 120M  1
15BPEX-150C BARRIER PIPE  15MM X 150M  1

PEX BARRIER PIPE

Supplied with Speedfit Pipe Inserts and Collet Clips.

Connects  to  a  Master  Wiring  Centre  to
give an additional 4 or 6 zones.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFH4ZS

WIRING CENTRE SLAVE 4 ZONE

1

JGUFH6ZS

WIRING CENTRE SLAVE 6 ZONE

WIRING CENTRE SLAVE

A  3  metre  long  cable  connects  a  non  electrical probe  to  a
room thermostat.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHTHKIT

WET AREA PROBE + COVER

1

WET AREA PROBE + COVER

Used  in  conjunction  with  the  Room
Thermostat  with  set  back  control  or
Digital Room Thermostat, the kit is used
in areas where the use of 240v would be
a problem.

Used  to  connect  the  wiring  from  thermostat,  actuators,
boiler and pump and manage the control of the underfloor
heating system.

The Programmable Room Thermostat is a fully programmable
electronic room thermostat which can be set to give each
zone an individual time and temperature control.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHPRS

PROGRAMMABLE ROOM 

1

THERMOSTAT

PROGRAMMABLE ROOM THERMOSTAT

If specified, one timer is needed for each manifold in the
system. The timer provides centralised control of the set
back  functions  for  the  whole  manifold  via  a  digital
programmer. The timer acts as a timed switch to alternate
between ‘daytime’ and ‘Set Back’ time.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHTIMER-C CENTRALISED SYSTEM TIMER 

1

CENTRALISED SYSTEM TIMER

To be used with a Speedfit Set Back Thermostat.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHTIMER-R

REMOTE SYSTEM TIMER 

1

REMOTE SYSTEM TIMER

A 4 channel programmer. Ideal for installations where the
system timer needs to be located away from the manifold.
Can also be used, via a Master Wiring Centre, to control
the set back for up to 4 Speedfit Room Thermostats. On a
larger  system  the  Remote  System  Timer  can  be  used  to
replace  a  number  of  individual  programmers,  controlling
say underfloor heating, radiators and hot water.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHSP400

390mm x 1000mm

1

JGUFHSP250

390mm x 250mm

1

JGUFHSP165

165mm x 1000mm

1

SPREADER PLATES

Spreader Plates are available for timber flooring using either traditional joists or TJI Joists.

Actuators are attached to the individual
heating circuits on the manifold, providing
individual control to a room or zone.

They open or close the flow of water and are controlled
by a thermostat or programmer. 

P

ART

D

ESCRIPTION

S

IZE

P

ACK

N

O

.

Q

TY

15BPB-50C

BARRIER PIPE 

15MM X 50M 

1

15BPB-100C

BARRIER PIPE  15MM X 100M  1

15BPB-120C

BARRIER PIPE  15MM X 120M  1

15BPB-150C

BARRIER PIPE  15MM X 150M  1

POLYBUTYLENE BARRIER PIPE

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

SPUFH1

MIXING VALVE CARTRIDGE KIT

1

SPUFH2

PUMP PACK FLOW TEMP GAUGE

1

SPUFH3

OVER HEAT STAT

1

SPUFH4

MANIFOLD FLOWMETER

1

SPUFH5

MANIFOLD BALANCING VALVE

1

SPUFH6

DUST CAP FOR BALANCING VALVE

1

UNDERFLOOR HEATING SPARE PARTS

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHMANEXT MANIFOLD EXTENSION KIT 1

MANIFOLD EXTENSION KIT

Enables a manifold to be extended
by one or more zones.

Spreader  Plates  390  x  1,000mm  and  390  x  250mm  are 
laid  across  traditional  joists  and  fixed  in  place  using  a
hand stapler.

Spreader  Plates  165  x  1000mm  can  be  used  with
traditional and TJI joists. They are fixed to the underside
of the floor using staples or screws. 

Speedfit Pipe is fixed in the grooves of the plates.

When  the  plates  and  pipework  have  been  installed,
insulation  is  placed  in  the  void  below  the  plates  to
minimise downward heatloss.

P

ART

D

ESCRIPTION

S

IZE

P

ACK

N

O

.

Q

TY

JGUFHSTAPLE

PIPE STAPLES

60mm

300

JGUFHGUN

STAPLE GUN 

-

1

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHEDGE

25 METRE ROLL

1

EDGE INSULATION STRIP

Black Staples are barbed to ensure a secure fixing to
the  insulation.  Easy  fixing  is  carried  out  by  using  a
Staple  Gun,  securing  pipe  to  the  insulation  with  an
easy repeatable action.

Supplied in 25 metre rolls, the edge insulation
strip is placed round the edge of each room to
provide insulation of the heated floor.

PIPE FIXING SYSTEMS

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHRAIL 

2 METRE LONG

16

JGUFHPIN

RAIL PINS FOR ABOVE 

100

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHCLIP

FLOOR CLIP

100

JGUFHTOOL FOR EASY FIXING OF FLOOR CLIPS

1

Mounting Rails offer a quick installation of 15mm pipe.
Supplied 2 metres long, the rails are pre scored every
100mm for easy cutting. The rail can be secured to the
insulation using red Rail Pins.

Floor  Clips  screw  easily  into  insulation,  they
are best installed using a Fixing Tool.

Works in conjunction with a Centralised or Remote System Timer

P

ART

P

ACK

N

O

.

Q

TY

JGUFHMANELB

1 PAIR

MANIFOLD ELBOW CONNECTOR

A  mains  operated  room  thermostat.  The  temperature  is
set  manually  to  ‘Daytime’  temperature  and  reduced  by
4

o

C to ‘Setback’ temperature by a Centralised or Remote

System  Timer.  It  has  a  manual  override  for  permanent
‘Daytime’ or permanent ‘Setback’ temperature and can be
used in conjunction with a Wet Area Probe.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHTHDIG

DIGITAL ROOM 

1

THERMOSTAT

DIGITAL ROOM THERMOSTAT

Works in conjunction with a Centralised or Remote System Timer

Enables  a  Pump  Pack  and
Manifold  to  be  installed  at  90º  to
each other.

P

ART

D

ESCRIPTION

P

ACK

N

O

.

Q

TY

JGUFHTILE

Floor Tile

12

1400mm x 800mm

FLOOR PANELS

Supplied  in  packs  of  12,  Speedfit  Floor  Tiles
have an 11mm layer of insulation for support
and additional thermal insulation.

Summary of Contents for Speedfit

Page 1: ...rposes only Subject to our Terms and Conditions of Sale available on request Z2105 217 10 07 No s 95 3177 BS7291 KM39767 AVAILABLE FROM THE PUSH FIT SOLUTION FOR PLUMBING HEATING SYSTEMS UK PRODUCT RA...

Page 2: ...ducts A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development 01 02 Technical Support Our national team of Technical...

Page 3: ...s application Speedfit fittings suitable for central heating systems can withstand temperatures up to 114 C intermittently for short periods Speedfit fittings shown as not suitable for central heating...

Page 4: ...ead The O ring on the Superseal Pipe Insert provides a secondary seal against the bore of the fitting A good connection has been made Gap between Cap and Flange Pipe mark indicates full insertion Twis...

Page 5: ...e connectors are useful when replacing existing brassware or in other confined spaces Coupling up to a supply is easy The pipe is simply pushed home into the Speedfit connection and is instantly secur...

Page 6: ...28 x 22 PEMSTC1514 15mm x 1 2 BSP PEMSTC1516 15mm x 3 4 BSP PEMSTC2216 22mm x 3 4 BSP PEMBTC1514 15mm x 1 2 BSP PART NO SIZE MM PSE4610W 10 PSE4615W 15 PSE4622W 22 Suitable for central heating systems...

Page 7: ...50mm long 1000mm long PART NO SIZE MM X MALE FLX48 12 x M10 FLX28 15 x M10 FLX29 15 x M12 FOR MONOBLOC MIXERS PART NO SIZE MM X BSP PART NO SIZE MM X BSP FLX36P 15 x 1 2 ELBOW PATTERN 300mm long 300mm...

Page 8: ...15BPEX 120C 15mm x 120m 15BPEX 150C 15mm x 150m 22BPEX 25C 22mm x 25m 22BPEX 50C 22mm x 50m Suitable for central heating systems Coils The pipe has an inner barrier to stop the ingress of atmosphere...

Page 9: ...Copper pipe PE copper coupler MDPE pipe with Pipe Insert Collet clip Speedfit Pipe Speedfit pipe should never be connected directly to a boiler Although most modern boilers have a high limit thermost...

Page 10: ...M M M M M M P P Plastic M Metal NB All Waste Pipes are plastic 1 Supplementary bonding is carried out to the earth terminal of protective conductors of class I and class II equipment within the bathro...

Page 11: ...rs does not affect the fire resistant properties of the structure Speedfit pipework can be easily cabled through studwork and within wall systems as well as behind dot and dab plasterboard installatio...

Page 12: ...ntrolled by one or more thermostats which signal the Pump Pack when heat is required 21 22 RADIATOR SYSTEM AND HEAT GRADIENT UNDERFLOOR HEATING SYSTEM An Underfloor Heating System heats mainly by radi...

Page 13: ...ntralised control of the set back functions for the whole manifold via a digital programmer The timer acts as a timed switch to alternate between daytime and Set Back time PART DESCRIPTION PACK NO QTY...

Page 14: ...on of the outside walls and windows will determine the pattern of the pipe layout The counterflow pattern is recommended although other options are shown below Single Serpentine Double Serpentine Trip...

Page 15: ...nst the face of fitting With the collet held in this position the pipe can be withdrawn We recommend the replacement of the O ring and collet before making a new connection Remove collet cover pull ou...

Page 16: ...ulose based paints paint thinners or strippers solder flux or acid based descalents or aggressive household cleaning products Exposure to sunlight Speedfit products when used indoors are not affected...

Reviews: