3 Year Limited Warranty
Graham-Field warrants to the original retail purchaser that this product is free from defects
in material and workmanship for a period of 3 years from the date of purchase. This
warranty does not cover failures resulting from misuse, abuse, alteration of the John Bunn
Nebulizer System, use of improper components or failure to comply with the operating
instructions. This warranty does not include the Nebulizer System tubing or accessories.
All requests for warranty service should include the model number of your John Bunn
Nebulizer System, proof of purchase (including date of purchase), your phone number and
the nature of your service request. Graham-Field will either repair or at its option replace
free of charge any parts necessary to correct defects in material or workmanship covered
by this limited warranty.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER ORAL,
WRITTEN, EXPRESS OR IMPLIED. THERE ARE NO WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, EXCEPT FOR
THOSE IMPLIED WARRANTIES ARISING BY OPERATION OF LAW WHICH ARE
LIMITED IN DURATION TO THE 1 YEAR TERM OF THIS WARRANTY. GRAHAM-FIELD’S
LIABILITY, WHETHER BASED ON CONTRACT, TORT, WARRANTY, STRICT LIABILITY,
OR ANY OTHER THEORY, SHALL NOT EXCEED THE PRICE OF THE INDIVIDUAL JOHN
BUNN NEBULIZER SYSTEM WHICH IS THE BASIS OF THE CLAIM. IN NO EVENT
SHALL GRAHAM-FIELD BE LIABLE FOR ANY LOSS OF PROFITS, FACILITIES,
EQUIPMENT OR OTHER INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts, or allow the
exclusion or limitation of incidental, consequential, or special damages, so the above
limitations or exclusions may not apply to you. This warranty gives you specific legal
rights. You may also have other rights which vary from state to state

Summary of Contents for JB0112-066 NANO-SONIC

Page 1: ... future reference Caution Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device MODEL JB0112 066 COMPRESSOR NEBULIZER JB0112 066 INS LABRevA05 NANO SONIC ...

Page 2: ...eld warrants that this device has been produced using high quality materials and it complies with the safety rules in force both domestically and internationally The John Bunn Nano Sonic Nebulizer operates on ultrasound which produces the drug solution vibration and turns it into mist Effective and quick results are achieved without side effects This model comes with the exclusive Closed Water Cha...

Page 3: ...re than 8 ml of solution into the medication cup 7 Do not leave drug solution in the medication cup when the device is not being used 8 Do not scrape or pierce the medication cup cover 9 Do not touch the medication cup or the drug solution while the device is being used 10 Do not dip the nebulizer in water 11 Children should only use the device under adult supervision 12 To avoid infections and co...

Page 4: ...4 4 Clear Housing Air Chamber Main body Power Indicator ON OFF Switch Power Connector AC Adapter Adapter Top cover OPTIONAL Car lighter adapter Nasal piece Mouth piece Air Filter Spare Parts Description ...

Page 5: ...ebulizer and contact the authorized Service Agent 4 Attach the unit to the power connector 5 Press ON switch The green light will turn on and the unit will start to operate Adjust the air regulator to the desired intensity 6 The unit will automatically turn off at 3 minutes If you wish to continue nebulizing check if the medication amount in the pool is sufficient Add more if necessary Then press ...

Page 6: ...move the pieces from the cleaning solution Rinse them with warm tap water and let them air dry Keep the pieces into a tightly sealed bag Do not dry them with a towel Clean the outer surface with a dry piece of cloth WARNING In order to avoid infections it is highly recommended to clean the pieces after each use Only nebulize solutions prescribed by a doctor and follow the doctor s instructions car...

Page 7: ...Incorrectly connected to power source 2 No power 3 The AC Adapter is not connected 1 Check the plug is properly connected 2 Check that power is on 3 Check the AC Adapter is properly connected The mist does not come out There is no solution in the cup Pour some drug solution into the medication cup Little mist is delivered 1 The air filter is dirty 2 There is not enough solution in the cup 3 Little...

Page 8: ...ight 0 57 lbs 260 g Device dimensions 3 2 x 6 6 x 2 3 83 5 x 169 x 60 mm Operating temperature and humidity 41ºF to 104ºF 30 to 95 RH 5º to 40º C 30 to 95 RH Storage temperature and humidity 33 8ºF to 104ºF 10 to 95 RH 1º to 40º C 10 to 95 RH Atmospheric pressure range for transport and storage 500 1060 mb The Closed Water Chamber contains a solution of Benzalkonium Chloride at 0 01 The specificat...

Page 9: ...overed by this limited warranty THIS LIMITED WARRANTY IS IN LIEU OFALL OTHER WARRANTIES WHETHER ORAL WRITTEN EXPRESS OR IMPLIED THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE EXCEPT FOR THOSE IMPLIED WARRANTIES ARISING BY OPERATION OF LAW WHICH ARE LIMITED IN DURATION TO THE 1 YEAR TERM OF THIS WARRANTY GRAHAM FIELD S LIABILITY WHETHER BASED ON CONTRACT TORT WARRANT...

Page 10: ...e Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 http www grahamfield com JB0112 066 INS LABRevA05 NECO 21180 ...