It operates on three types of power sources: the main supply via AC adapter, the
optional car lighter adapter and the optional rechargeable battery pack.

CAUTION: As per USA Federal regulations this product can only be sold under medical

prescription.

Recommendations
1. 
Read the manual carefully before using the device and keep it in case you need

further information in the future.

2. Do not turn the device on if there is no drug solution in the medication cup.
3. Disconnect the nebulizer when it is not being used.
4. Do not remove the medication cup cover while the device is operating.
5. Do not expose the nebulizer to a heat source.
6. Do not pour more than 8 ml. of solution into the medication cup.
7. Do not leave drug solution in the medication cup when the device is not being used.
8. Do not scrape or pierce the medication cup cover.
9. Do not touch the medication cup or the drug solution while the device is being used.
10. Do not dip the nebulizer in water.
11. Children should only use the device under adult supervision.
12. To avoid infections and contagion the accessories should not be shared by different

patients. They are intended for personal use.

13. Use the unit intermittently. Maximum operating period: 30 minutes. 

Rest period: 30 minutes.

14. Graham-Field warrants the quality of the liquid contained in the Closed Water

Chamber for a period of 3 years. This solution can be changed easily by the
authorized dealer.

15. This device can only be repaired by the local dealer’s authorized service agents.

Summary of Contents for JB0112-066 NANO-SONIC

Page 1: ... future reference Caution Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device MODEL JB0112 066 COMPRESSOR NEBULIZER JB0112 066 INS LABRevA05 NANO SONIC ...

Page 2: ...eld warrants that this device has been produced using high quality materials and it complies with the safety rules in force both domestically and internationally The John Bunn Nano Sonic Nebulizer operates on ultrasound which produces the drug solution vibration and turns it into mist Effective and quick results are achieved without side effects This model comes with the exclusive Closed Water Cha...

Page 3: ...re than 8 ml of solution into the medication cup 7 Do not leave drug solution in the medication cup when the device is not being used 8 Do not scrape or pierce the medication cup cover 9 Do not touch the medication cup or the drug solution while the device is being used 10 Do not dip the nebulizer in water 11 Children should only use the device under adult supervision 12 To avoid infections and co...

Page 4: ...4 4 Clear Housing Air Chamber Main body Power Indicator ON OFF Switch Power Connector AC Adapter Adapter Top cover OPTIONAL Car lighter adapter Nasal piece Mouth piece Air Filter Spare Parts Description ...

Page 5: ...ebulizer and contact the authorized Service Agent 4 Attach the unit to the power connector 5 Press ON switch The green light will turn on and the unit will start to operate Adjust the air regulator to the desired intensity 6 The unit will automatically turn off at 3 minutes If you wish to continue nebulizing check if the medication amount in the pool is sufficient Add more if necessary Then press ...

Page 6: ...move the pieces from the cleaning solution Rinse them with warm tap water and let them air dry Keep the pieces into a tightly sealed bag Do not dry them with a towel Clean the outer surface with a dry piece of cloth WARNING In order to avoid infections it is highly recommended to clean the pieces after each use Only nebulize solutions prescribed by a doctor and follow the doctor s instructions car...

Page 7: ...Incorrectly connected to power source 2 No power 3 The AC Adapter is not connected 1 Check the plug is properly connected 2 Check that power is on 3 Check the AC Adapter is properly connected The mist does not come out There is no solution in the cup Pour some drug solution into the medication cup Little mist is delivered 1 The air filter is dirty 2 There is not enough solution in the cup 3 Little...

Page 8: ...ight 0 57 lbs 260 g Device dimensions 3 2 x 6 6 x 2 3 83 5 x 169 x 60 mm Operating temperature and humidity 41ºF to 104ºF 30 to 95 RH 5º to 40º C 30 to 95 RH Storage temperature and humidity 33 8ºF to 104ºF 10 to 95 RH 1º to 40º C 10 to 95 RH Atmospheric pressure range for transport and storage 500 1060 mb The Closed Water Chamber contains a solution of Benzalkonium Chloride at 0 01 The specificat...

Page 9: ...overed by this limited warranty THIS LIMITED WARRANTY IS IN LIEU OFALL OTHER WARRANTIES WHETHER ORAL WRITTEN EXPRESS OR IMPLIED THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE EXCEPT FOR THOSE IMPLIED WARRANTIES ARISING BY OPERATION OF LAW WHICH ARE LIMITED IN DURATION TO THE 1 YEAR TERM OF THIS WARRANTY GRAHAM FIELD S LIABILITY WHETHER BASED ON CONTRACT TORT WARRANT...

Page 10: ...e Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 http www grahamfield com JB0112 066 INS LABRevA05 NECO 21180 ...