A:the Installation location of
overflow high water level sensor.
B:the Installation location of
overflow low water level sensor.
1. C:the Installation location of pump
dryed high water level sensor.
2. D:Pump outlet
,
the Installation
location of pump dryed low water
level sensor.
3. S about 1-3 m .
B
B1 connect SY_IN
B2 connect COM
A1 connect DG_IN
A2 connect COM
Figure6-8
The installation figure of Sensor A
If you selected water level sensor B, then water sensor installation method is shown below:
connect to COM
connect to DG_IN
connect to COM
connect to SY_IN
A:the Installation
location of overflow
water level sensor.
1. B:the Installation location of
pump dryed water level sensor.
2. C:Pump outlet.
3. S about 1-3 m .
A
B
C
S
For dry protection, the end
with cable of sensor should
be upwards
For over-
flow protection, the end
with cable of sensor s
hould be downwards
The
Figure6-9
The installation figure of Sensor B