Control panel:
Amperage:
Selection of supplied current (FLASH
function) or battery capacity (CHAR-
GE function)
Selection of current/voltage display
Function:
Selection of function (supply mode
“FLASH” or battery charging “CHARGE”
as well as Recovery)
Available modes:
Battery
charging
“CHARGE”
Battery type
“Batt.”
AGM/EFB (max. 14,7 V)
LiFePO4 (max. 14,4 V)
STD (max. 14,4 V)
Battery capacity
“Amperage”
300-600 Ah;
150-300 Ah;
50-150 Ah;
5-50 Ah
Power
cable mode
“FLASH”
Voltage output
“Volt”
14,8 V;
14,4 V;
13,8 V
Current output
“Amperage”
60 A;
30 A;
15 A;
5 A
“Recovery”
Regenerating mode for sulphatised batteries. Select by holding the function key
depressed for 3 seconds (display: “REC”). No error messages are displayed
during the charging process. An increased voltage of 15.5 V is forced.
Note! Only run recovery mode with the battery disconnected from the ve-
hicle in order to avoid damage! Do not charge lithium batteries in recovery
mode under any circumstances!
The CHARGE LED flashes.
Full: Battery is full and trickle
charging
Charging: Battery is charging
Fault: Battery is damaged
Reverse: Polarity reversal
ON: Ready for use
Volt/Batt:
Selection of supply voltage (FLASH
function) or battery type (CHARGE
function)
Starts/stops
the current/vol-
tage output
{