SECTION 3 - CHASSIS, PLATFORM & SCISSOR ARMS
3121325
– JLG Lift –
3-25
3.9 GROUND CONTROL PANEL
Removal:
DISCONNECT GROUND CONTROL PANEL (1) FROM BATTERY
BEFORE REMOVING AND/OR SERVICING.
1. Disconnect all plugs and wires from the back of the
control panel.
2. Remove the panel from the the Electrical Compart-
ment (2) by removing the six Bolts (3), Nuts (4), and
twelve Flatwashers (5).
NOTE:
When removing the control panel, take care not to
damage any plug receptacles and switches.
Installation:
1. Attach the Ground Control Panel to the Electrical
Compartment with the Bolts, Flatwashers, and Nuts.
2. Carefully attach all wires and reconnect to battery.
3. Make certain all LED’s and switches work properly.
1
2
3
4
5
1. Ground Control Panel
2. Electrical Compartment
3. Bolt, M6 x 20mm
4. Nut, M6
5. Flatwashers, M6
Figure 3-23. Ground Control Panel Removal