SECTION 2 - GENERAL
3121325
– JLG Lift –
2-11
Table 2-3. Preventive Maintenance and Safety Inspection
AREA
INTERVAL
Daily
Weekly
100 Hours
(3 Months)
200 Hours
(6 Months)
400 Hours
(1 year)
PLATFORM
1. Controller
1,11
2. Switches
1,11
3. Placards and Decals
1,2
4. Control Tags
1,2
5. Hoses and Cables
4,8
6. Wear Pads
8,12
7. Handrails and Chains
1,4
CHASSIS
1. Battery
3
5
2. Hydraulic Pump
1
5
3. Valves
1
5
4. Hydraulic Filter
ANNUAL
5. Hydraulic Hoses and Tubing
1
5
6. Hydraulic Oil Tank
5
3,4
8. Lift Cylinder
1,12
5,6,13
4
9. Limit Switch
1,7
10. Tilt Alarm Switch
1,7
11. Placards and Decals
1,2
12. Wheel and Tire Assemblies
1
8,9
13. Drive Motors
1,5,6
14. Drive Brakes
1,6
8
15. Drive Torque Hubs
1,3,5,6
16. Steer Cylinder
1
5,6,13
4
17. Steer Components
1
4,6
8
18. Wheel Bearings
8
12
19. Scissor Arms
1,4
20. Safety Props
1,4
21. Sliding Wear Pads
8,12
22. Pivot Pins/Bolts
1,4
7,8
23. Switches, Ground Control
1,11
24. Control Tags
1,2
25. Frame - including doubler plate,
gussets, and surrounding area
1, 4
Summary of Contents for 80SL
Page 1: ...Service Maintenance Manual Model 80SL 3121325 March 24 2011...
Page 2: ......
Page 24: ...SECTION 1 SPECIFICATIONS 1 12 JLG Lift 3121325 NOTES...
Page 36: ...SECTION 2 GENERAL 2 12 JLG Lift 3121325 NOTES...
Page 80: ...SECTION 3 CHASSIS PLATFORM SCISSOR ARMS 3 44 JLG Lift 3121325 NOTES...
Page 106: ...SECTION 4 HYDRAULICS 4 26 JLG Lift 3121325 NOTES...
Page 155: ...SECTION 6 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121325 JLG Lift 6 37 NOTES...
Page 161: ......