![JLG 600A Operation And Safety Manual Download Page 135](http://html.mh-extra.com/html/jlg/600a/600a_operation-and-safety-manual_2020045135.webp)
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
3121615
– JLG Lift –
6-31
6.6
PROPANE FUEL FILTER REPLACEMENT
Removal
1.
Relieve the propane fuel system pressure. Refer to Propane
Fuel System Pressure Relief.
2.
Disconnect the negative battery cable.
3.
Slowly loosen the Filter housing and remove it.
4.
Pull the filter housing from the Electric lock off assembly.
5.
Remove the filter from the housing.
6.
Locate Filter magnet and remove it.
7.
Remove and discard the housing seal.
1.
Electric Lock Off Solenoid
2.
Housing Seal
3.
Filter Magnet
4.
Filter Housing
5.
Electrical Connector
6.
Fuel Outlet
7.
O-ring
8.
Filter
9.
Fuel Inlet
10. Ring
Figure 6-10. Filter Lock Assembly