![JLG 340AJ Service And Maintenance Manual Download Page 319](http://html1.mh-extra.com/html/jlg/340aj/340aj_service-and-maintenance-manual_2020028319.webp)
SECTION 6 - JLG CONTROL SYSTEM
3121259
– JLG Lift –
6-73
DRIVE – CURRENT FEEDBACK
READING TOO LOW
33331
The Ground Module calls for current greater than 250mA, but the
actual current is at least 125mA less than the called for current for
more than 1 second
The Ground Module suspends
Drive Forward/Reverse com-
mands and reverts to Open Cur-
rent loop control for Drive; Drive
speed is limited to Creep after
both Drive Forward/Reverse
controls have been returned to
neutral and the machine is not
Enabled.
Part of the commanded current
is being divided either prior to
the solenoid connection or on
the ground return path. Inspect
wiring for physical damage and
check for wire continuity and a
low resistance return path.
Cycle power to clear the fault.
LIFT UP VALVE – SHORT TO
GROUND
33406
The Ground Module detects a short to ground at the Lift Up Valve out-
put.
Lift Up is disabled; Lift Down
speed is limited to Creep
Inspect wiring for physical
damage and check for wire
continuity. Check for coil dam-
age or shorting condition in
connector. Cycle power to clear
the fault.
DRIVE – LOSS OF CURRENT
FEEDBACK
33410
Measured feedback current is less than 225mA while Ground Module
output is greater than 40% (Displayed on Analyzer DIAGNOSTICS
menu).
The Ground Module suspends
Drive Forward/Reverse com-
mands and reverts to Open Cur-
rent loop control for Drive; Drive
speed is limited to Creep after
both Drive Forward/Reverse
controls have been returned to
neutral and the machine is not
Enabled.
Part or all of the commanded
current is being diverted from
the ground return path. Inspect
wiring for physical damage and
check for wire continuity and a
low resistance return path.
Cycle power to clear the fault.
SWING VALVES – SHORT TO
BATTERY
33412
The Ground Module detects a short to battery at either the Swing
Right or Swing Left valve
Ground Module Swing Left and
Right outputs are disabled and
open the ground current return
path is open circuited.
Inspect wiring for physical
damage and check for wire
continuity. Cycle power to clear
the fault.
TOWER LIFT – CURRENT FEED-
BACK READING TOO LOW
33413
The Ground Module calls for current greater than 250mA, but the
actual current is at least 125mA less than the called for current for
more than 1 second
The Ground Module suspends
Tower Lift commands and
reverts to Open Current loop
control for Tower Lift; Tower Lift
speed is limited to Creep after
both Tower Lift Up/Down con-
trols have been returned to
neutral and the machine is not
Enabled.
Part of the commanded current
is being divided either prior to
the solenoid connection or on
the ground return path. Inspect
wiring for physical damage and
check for wire continuity and a
low resistance return path.
Cycle power to clear the fault.
SWING – CURRENT FEEDBACK
READING TOO LOW
33414
The Ground Module calls for current greater than 250mA, but the
actual current is at least 125mA less than the called for current for
more than 1 second
The Ground Module suspends
Swing Left/Right commands
and reverts to Open Loop Cur-
rent control for Swing; Swing
speed is limited to Creep after
both Swing Left/Right have
been returned to neutral and
the machine is not Enabled
Part of the commanded current
is being divided either prior to
the solenoid connection or on
the ground return path. Inspect
wiring for physical damage and
check for wire continuity and a
low resistance return path.
Cycle power to clear the fault.
Table 6-15. Fault Code Troubleshooting Information
Help Message
DTC
Condition Producing DTC
Control System Response or
Machine Condition
Corrective Action/
Operational Requirement
for Function Movement
and/or to Clear Fault
Summary of Contents for 340AJ
Page 1: ...Service and Maintenance Manual Model 340AJ P N 3121259 June 27 2017...
Page 2: ......
Page 10: ...vi JLG Lift 3121259 TABLE OF CONTENTS SECTION NO TITLE PAGE NO Thispageleftblankintentionally...
Page 15: ...3121259 JLG Lift xi LIST OF FIGURES FIGURE NO TITLE PAGE NO Thispageleftblankintentionally...
Page 18: ...xiv JLG Lift 3121259 LIST OF TABLES TABLE NO TITLE PAGE NO Thispageleftblankintentionally...
Page 42: ...SECTION 2 GENERAL 2 12 JLG Lift 3121259 NOTES...
Page 69: ...SECTION 3 CHASSIS TURNTABLE 3121259 JLG Lift 3 27 Figure 3 24 Bearing Pressing Tool...
Page 71: ...SECTION 3 CHASSIS TURNTABLE 3121259 JLG Lift 3 29 Figure 3 27 Bearing Nut Wrench...
Page 134: ...SECTION 3 CHASSIS TURNTABLE 3 92 JLG Lift 3121259 NOTES...
Page 157: ...SECTION 4 BOOM PLATFORM 3121259 JLG Lift 4 23 Figure 4 8 Rotator Counterbalance Valve...
Page 218: ...SECTION 5 HYDRAULICS 5 58 JLG Lift 3121259 Figure 5 32 Fasteners and Plugs Sheet 1 of 2...
Page 219: ...SECTION 5 HYDRAULICS 3121259 JLG Lift 5 59 Figure 5 33 Fasteners and Plugs Sheet 2 of 2...
Page 236: ...SECTION 5 HYDRAULICS 5 76 JLG Lift 3121259 Figure 5 39 Gear Pump Cutaway...
Page 246: ...SECTION 5 HYDRAULICS 5 86 JLG Lift 3121259 Figure 5 40 Oil Sampling Port...
Page 256: ...SECTION 6 JLG CONTROL SYSTEM 6 10 JLG Lift 3121259 Figure 6 3 Ground Module Sheet 1 of 4...
Page 273: ...SECTION 6 JLG CONTROL SYSTEM 3121259 JLG Lift 6 27 Figure 6 16 Analyzer Machine Setup Menu...
Page 274: ...SECTION 6 JLG CONTROL SYSTEM 6 28 JLG Lift 3121259 Figure 6 17 Analyzer Calibrations Menu...
Page 336: ...SECTION 6 JLG CONTROL SYSTEM 6 90 JLG Lift 3121259 NOTES...
Page 368: ...SECTION 7 BASIC ELECTRICAL INFORMATION SCHEMATICS 7 32 JLG Lift 3121259 NOTES...
Page 369: ......