Heat Input / Gas Consumption / Orifice (Injector) Data
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Gas Specifications for Dryers Going to CE Countries
**
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Fuel
Consumption
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb
Btu/hr
kW
DMS
mm
mb
Natural (I
2H
/I
2E
)
1,000
15-30
40,000
11.72
1.133 M
3
/H
30
3.264
1
6.7
Natural (I
2L
)
830
20-35
40,000
11.72
1.365 M
3
/H
30
3.264
1
9.2
Natural (I
2ELL
)
830
15-30
40,000
11.72
1.365 M
3
/H
30
3.264
1
9.2
*
Natural (I
2E+
)
1,000
20
40,000
11.72
1.133 M
3
/H
38
2.578
1
—
830
25
40,000
11.72
1.365 M
3
/H
38
2.578
1
—
*
Butane (I
3+
)
3,175
28-30
40,000
11.72
0.845 kg/H
52
1.613
1
—
*
Propane (I
3+
)
2,500
37
40,000
11.72
0.845 kg/H
52
1.613
1
—
Butane (I
3B/P
)
3,175
28-30/50
40,000
11.72
0.845 kg/H
49
1.854
1
18.0
Propane (I
3P
)
2,500
28-30/50
40,000
11.72
0.845 kg/H
49
1.854
1
23.0
Gas Specifications for Dryers Going to Rest of the World
**
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
in wc
Btu/hr
kW
DMS
mm
in wc
Natural
1,000
7.0-13.0
40,000
11.72
30
3.264
1
3.0
*
Liquid Propane
2,500
11.0
40,000
11.72
49
1.854
1
10.0
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.