18
ERROR MESSAGE & TROUBLE SHOOTING
There is an ASA system (Adjustable Shock Absorbing system) installed on the right
side of main frame. By turning the knob, user can change shock intensity from soft
(1) (decrease 60%) to Firm (5) (decrease 20%). Do not adjust it when some one
is running on the machine.
ASA OPERATION
E1 (Error 1):
When the machine starts but computer could not read the signal from sensor for 7 seconds,
E1 will be shown on the computer.
E6 (Error 6):
When the machine starts but computer could not read the VR signal from incline motor for 6 seconds,
E6 will be shown on the computer.
If any above trouble happens, please consult the distributor.
E3 (Error 3):
It happens only in HRC mode (H1, H2, or H3) when user
’
s heart rate is 20 beats more than target
heart rate and last for over 30 seconds. For your safety, you should stop running when E3 appears.
SMELL
If any smell comes out from motor, please firstly spray out some silicone on the running board
(Please refer to page : RUNNING BOARD MAINTENANCE), and see if the situation improves. Then
onsult the distribu-tor for necessary help.
WARNING:
For safety concern, suggest do not operate tablet or laptop when you are running or walking at
high speed.
TRANSPORTATION:
This machine is equipped with 4 transport wheels. For reference, tilting the frame in one side to
screw in 2 balancers, then do the same to screw in another 2 balancers in another side. Then fold
the frame up, the unit can be easily moved.