4.Under the Export Limit, you can see the setup options below after pressing Enter:
Chart 6.10
Export limit is used for users to control the energy flowing to the grid. If this function is
enabled, the feeding power to grid will be equal or less than the setup value.
The purpose of the Fail Safe function is to ensure that should any part of the ELS fail, the
Active Power exported across the Connection Point will drop to the Agreed Export
Capacity or less within the specified time.
Note: 1.Default value is 00.0%
Fail safe works only in meter mode
5.Under the default set, you can see the setup options below after pressing Enter:
Chart 6.11
Default set is “resume to default setting ”, please don't use it unless it's necessary.
6.4
Communication
6.4.1 Use of USB-A Port
USB-A port is mainly for firmware update. Through USB connection, we can quickly
update the software of machine. You can see USB-A as below:
Chart 6.12
Note:
USB is only used for firmware update. Customer can't use it for charging.
6.4.2 The JKS's Monitoring
Users can through the following communication solution to monitor the JKS.
Note:
This monitoring can only be used by JKS's Shine server/Shine phone's monitor provided
by the company.JKS-WIFI-BI / JKS-LINK-BI through USB interface, using computer
terminal / mobile phone for data monitoring.
Chart 6.13
The USB collector is connected
:
Chart 6.14
Whether it is a JKS-WIFI-BI/ JKS-LINK-BI collector; Connect to the remote monitoring
system, scan the QR code on the collector to download the APP. After the download is
complete, please prompt for operation. Please see the collector manual for details.
WorkMode
ExportLimit
WorkMode
WorkMode
ExportLimit: OFF
ON
Power Rate :
00.0%
Press
“enter”
key more
than 1 seconds to make sure
Press
“down”
key
to the next item
Press
key
to make sure
Range from 00.0% to 100.0% ,
and the accuracy
is
0.1%
WorkMode
Fail Safe: ON
OFF
Press
“Enter” Key to make
sure
Work Mode
Defult Set
Work Mode
Yes
Press
Key more than
3
seconds to make sure
“Enter”
“enter”
47
48
WIFI
Inverter side