7.3
Storage for modules
S/N
Operating Procedure
Photo
Control Point
1
The module would be best set on the flat
floor, stand side by side and place neatly.
To same color and current
modules, try to make sure
that they are placed together
for easy management.
2
1. If the ground is not flat or the slope is
small, the stacked package must be break
down, the short part of carton is facing
down, stand side by side and place
neatly.
2. Module are not allowed to place on
steep ground.
3. When second transportation, a special
person should be command to carry, and
it is prohibited to damage the packing
box.
The pallet should be pulled
firmly as following.
3
The module should be protect when
raining or wet, which wrapped by
waterproof.
It should be protected by
waterproof whether above
two methods.
If the installation is not
performed after the arrival of
the modules, the packaging
box must be kept in a dry
state and moved indoors. If
the packaging box is found to
be wet, it is recommended to
dry the modules and replace
the packaging box.
7.4 Storage for scattered modules
S/N
Operating Procedure
Photo
Control Point
1
If unpacked modules do not
installed completely.
It can not remain in the box for long time, if it is
necessary to storage the unpacked modules, we
suggest the following method.
2
Place the modules on the
pallet.
1. The pallet need to put on the flat ground.
2. The glass of first module need to face upward,
it need to face down from second module.
3. It can not more than 10 Pcs/pallet totally.
4. It is forbidden that carry module by cable of
junction box.
5. The modules should be stacked neatly, avoid
the glass blasting because of dislocation.
6. Do not allowed to carry modules in the this
case.
7. It is not allowed two or more adjacent modules
which have no corner protection
.