400W WALL INSTALLATION

800W & 1000W INSTALLATION

400w heaters - One mounting 
bracket must be used per installation 
(Supplied)

The brackets on the Aluminium 
heaters are suitable for wall and 
ceiling mounting.
 

1, Attach the panel bracket (B) to the rear 
of the heater with the four 10mm screws. 
Ensure that they are tight.

2, The wall bracket (A) is attached to the 
wall on 4 corners. This must be done at 
a suitable height and position with the 
correct fixings for the construction of 
wall. Use a spirit level to ensure that the 
bracket is straight.

3, Insert the grub screws into the wall 
bracket ensuring that the screw is only 
2-3mm in to the bracket.

4, The panel, with bracket (B) attached to 
the heater, can then be slid into the wall 
bracket (A). 

5Both retaining grub screws must 
be tightened to ensure that the 
heater is safely fixed to the wall
 (C). 
Use supplied 350mm screwdriver (retail 
customers)

Panel Bracket (B) into heater

Joined Brackets with grub screws (C)

Horizontal bracket positions for 800w & 1000w

One grub screw to be used in each bracket in the 

outer left and right fixing.

Vertical bracket positions for 800w & 1000w

All four grub screws to be used on top and 

bottom brackets

800w & 1000w heaters - Two mounting 
brackets must be used per installation 
(Supplied)

The brackets on the Aluminium 
heaters are suitable for wall and 
ceiling mounting.
 

1, Attach two panel brackets (B) to the 
rear of the heater with the four 10mm 
screws. Ensure that they are tight.

2, The wall brackets (A) are attached to 
the wall on 4 corners. This must be done 
at a suitable height and position with the 
correct fixings for the construction of 
wall. Use a spirit level to ensure that the 
bracket is straight. 

3, Insert the grub screws into the wall 
brackets ensuring that the screw is only 
2-3mm in to the bracket. 

Horizontal - 

Two retaining grub screws 

must

 be used. 

Vertical - All retaining grub screws 

must

 

be used. 

4, The panel, with brackets (B) attached 
to the heater, can then be slid into the 
wall bracket (A). 

5, Tighten the grub screw to ensure that 
the heater is safely fixed to the wall (C). 
Use supplied 350mm screwdriver (retail 
customers)

Summary of Contents for Infrared Heater

Page 1: ...Feel the Future of Heating Step out of the Shade and into the Sun Infrared Heating Instruction Manual Aluminium Infrared Heater...

Page 2: ...when installing and using the appliance 4 Modi cation of the heater in any way voids the warranty 5 Make sure that the appliance is in good condition prior to installation and do not use the appliance...

Page 3: ...Certi ed The Restriction of the Use of Certain Hazardous Substances RoHS in Electrical and Electronic Equipment Directive 2011 65 EU aims to prevent hazardous substances from entering the production...

Page 4: ...y time in order to avoid dangerous overheating The materials used for packaging is only to be used for transport and can be recycled Remove before use For disposal use dedicated recycling containers T...

Page 5: ...ask professional quali ed personnel The brackets on the Aluminium heaters are suitable for wall and ceiling mounting The heater bracket provides the option of hanging your heater in either landscape o...

Page 6: ...Bracket B into heater Joined Brackets with grub screws C Horizontal bracket positions for 800w 1000w One grub screw to be used in each bracket in the outer left and right fixing Vertical bracket posi...

Page 7: ...of wall See page 8 for measurements Advice To ensure the brackets mount correctly draw a straight line with a straight edge spirit level or laser level to align the fixing points for the two brackets...

Page 8: ...earthed and connected to a supply that is earthed If the appliance is mounted in the bathroom or shower the power line must be equipped with an RCD with maximum rated current of 30mA In humid environm...

Page 9: ...hnical problems contact a quali ed professional Do not attempt to repair it yourself Attempts to do so will invalidate your guarantee Disposal All ranges of our heaters are classed as electrical produ...

Page 10: ...Setting these unused rooms at a base rate of 16 17 will allow the room to stay warm until they are required to be boosted to 19 This is perfect for bedrooms offices and spare rooms Sizing the Heaters...

Page 11: ...om Trade www jigsawinfraredfactory com Phone 0121 794 2081 Solutions by Jigsaw LTD is a Limited Company registered in England and Wales Registered Office 1 St Josephs Court Trindle Road West Midlands...

Reviews: