Density 

Hornbeam  ..................................................................................... 400 – 500 kg per m³ 
Oak  ................................................................................................ 380 – 480 kg per m³ 
Beech  ............................................................................................ 350 – 450 kg per m³ 
Birch  .............................................................................................. 300 – 400 kg per m³ 
Poplar  ............................................................................................ 250 – 350 kg per m³ 

 

 
Loading of the fireplace with wood: 

MODUL-ART 67...................................................... 2,4 kg (maximum) dry wood per hour 
MODUL-ART 77...................................................... 2,8 kg (maximum) dry wood per hour 
MODUL-ART 16/9 .................................................. 3,2 kg (maximum) dry wood per hour 
MODUL-ART XL16/9……………………………………………..4,0 kg (maximum) dry wood per hour 

ATTENTION 

 

*************************************************************************** 
Overload  of  your  stove  can  have  significant  consequences  and  these  damages  will 
obviously not be covered by the guarantee: 
 

 

Distortion of the baffle; 

 

Bleaching of the glass; 

 

Deterioration of the vermiculite; 

 

Excessive expansion of the door, which could lead to a distortion. 

*************************************************************************** 

Furthermore, we recommend you: 

Do  not  burn  resinous  or  treated  wood  (e.g.  painted  wood)  or  any  other  material 
containing toxic products harmful to the environment, or which are aggressive for the 
components of the fireplace. 

Your fireplace is not designed to be used as an incinerator, only burn heating wood. 

Do not overcome the calorific value of wood. Pay attention to the calorific value of 
compressed logs. Half a compressed log at a time. 

 

 

Ideal rate : 15 % 

Energy efficiency 

Moisture rate (%) 

Summary of Contents for MODUL-ART

Page 1: ...jide be Modul ART EN June 2018 MANUAL FOR INSTALLATION USE AND MAINTENANCE MODUL ART Thank you for choosing a Jid stove We are convinced it will bring you comfort and warmth In order to get the best o...

Page 2: ...ER INSTRUCTIONS 4 Lighting the fire 4 Combustion 4 Wood Choice and use 5 MAINTENANCE OF THE STOVE 7 Maintenance 7 Cleaning of the glass 7 Door 7 Chimney sweeping 8 Spare parts Identification plate 8 I...

Page 3: ...he appliance may not be modified as it could present a real danger and will invalidate the warranty A list of our dealers installers is available on our site www jide be en Before using your fireplace...

Page 4: ...TENTION Before reloading open the door slowly to prevent smoke backdraft in the room To ensure optimal working do not remove completely ash of the stove The stove is designed to operate with the door...

Page 5: ...mbustion and the draught of the chimney strong wind fog When removing ash be careful with remaining embers During the fire the door must be closed Do NEVER use flammable liquids ex methanol to light o...

Page 6: ...an have significant consequences and these damages will obviously not be covered by the guarantee Distortion of the baffle Bleaching of the glass Deterioration of the vermiculite Excessive expansion o...

Page 7: ...ass or on warm glass with a glove 2 With a damp cloth and wood ash The window can be easily cleaned with a cloth or slightly damp absorbent paper that has been previously soaked in the cold white ash...

Page 8: ...ms A poker A cold grip A glove A connection plate dia 100 mm connection combustion air A plug plate and a fixing screw to close the air inlet of the back in case of connection from below A plug smoke...

Page 9: ...on To ensure an airtight connection adapted to the wished installation and to the good working of your stove contact your installer who will give you the helpful information The chimney section must i...

Page 10: ...ke Remove the metal sheet plug on the front of the air box which will permit to take the combustion air in the room Leave also open the air inlet on the back 2 Connect the outside air inlet to the bac...

Page 11: ...too fast Appliance overloaded with fuel Small diameter fuel Too important opening of the air for combustion Load the appliance reasonably 1 kg of dry wood per hour for 3 kW of power Ex 3 kg of dry woo...

Page 12: ...B laboratories Royal association of Belgian gas fitters meeting the European EN 13240 standard it was stated that The power in kW for Modul art 67 8 10 kW Modul art 77 9 11 kW Modul art 16 9 11 13 kW...

Page 13: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be Modul ART EN June 2018 13 CE MARKING PRODUCT FICHE EU 2015 1186...

Page 14: ...its return The following are excluded from the warranty Internal wear parts in contact with the flames and embers The vermiculite panels The joints of the door and ash box The window liable to underg...

Page 15: ...of the immobilisation of the appliance resulting from warranty operations are to the charge the customer The warranty is only provided through the dealer agent on presentation of the purchase invoice...

Page 16: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be Modul ART EN June 2018...

Reviews: