PDL5 User Manual
PDL5-UM-00001 Rev 001
39
when making very low backreflection measurements, terminate the fiber near
the DUT to eliminate reflections from the fiber itself.
Long Cables (for single-mode model only)
Terminate the cables near the devices or connectors being tested in order to
eliminate backreflection from the fiber.
Laser Stability
If the message “Source Unstable” or “LASER POWER LOW” is displayed, remove
the front connector panel, clean the front panel connectors, connect the
internal FC/APC connector to the detector adapter, and press the Power key to
set the meter to Power mode. The reading must be steady and higher than -10
dBm. If not, perform the procedure recommended in Table 9 when this
message is displayed.
Polarization Controller Issues
If the waveplates can't be moved to 0 position on start-up, or the
communication is lost with any of the driver boards, the following message will
appear: "WP MOTOR FAIL !".
If this message is displayed, there is a problem with the polarization controller.
Please contact JGR Optics for support.