background image

Measurements and Instrumentation 

Power supply 0 to 30 V DC 

Réf : 
281 048 

ENGLISH

 9 

 

General checks 

Adjust the voltage adjustment button.  The voltage value indicated on the 
display should vary as a result.  Turn the button clockwise to increase the 
value displayed and anti-clockwise to reduce it.  

Voltage and current must be present at the output terminals.  

5 Maintenance 

  This appliance contains high-precision components and must be 

handled and stored with the greatest care.  

 

Clean the displays using a soft cloth.  

 

The recommended storage temperature is – 10 to + 60°C. 

 

6 After-Sales 

Service 

 

This material is under a two year warranty and should be returned to our 
stores in the event of any defects.  
 
For any repairs, adjustments or spare parts, please contact: 
 

JEULIN - TECHNICAL SUPPORT 

Rue Jacques Monod 

BP 1900 

27 019 EVREUX CEDEX FRANCE 

+33 (0)2 32 29 40 50

 

 

Summary of Contents for 281 048

Page 1: ...Mesures et Instrumentation Measurements and Instrumentation Réf 281 048 Français p 1 English p 6 Version 7007 Alimentation 0 à 30 V continu Power supply 0 to 30 V DC ...

Page 2: ...glage grossier de la tension de sortie Tourner dans le sens des aiguilles d une montre pour augmenter la tension en sens inverse pour la diminuer 3 Bouton de réglage de l intensité Permet un réglage grossier du courant de sortie 4 Bouton de réglage de la tension Réglage fin Permet le réglage fin de la tension 5 Afficheur Indique la tension 6 Afficheur Indique l intensité du courant 7 Bornes de sor...

Page 3: ...mple un radiateur pendant une durée prolongée Ne pas utiliser l appareil lorsqu il fait froid sa température de service doit être comprise entre 0 C et 40 C Eviter de déplacer brusquement l alimentation d un endroit chaud à un endroit froid et vice versa au risque de provoquer la formation de condensation à l intérieur de l appareil 3 2 Eviter humidité et poussière Si l alimentation est placée dan...

Page 4: ... à 121 V alternatifs Vérifiez le type de fusible Utilisez le type de fusible correct afin de protéger l appareil contre les surintensités Si le fusible a sauté recherchez en la cause avec soin et remplacez le par un fusible du calibre spécifié Si vous n utilisez pas le bon fusible non seulement l appareil ne fonctionnera pas correctement mais aussi la panne peut s aggraver Vous devez donc veiller ...

Page 5: ... un courant doivent être présents sur les bornes de sortie 5 Maintenance Cet appareil contient des éléments de haute précision et doit donc être manipulé et stocké avec le plus grand soin Nettoyez les afficheurs à l aide d un chiffon doux La température de stockage recommandée et de 10 à 60 C 6 Services après vente La garantie est de 2 ans le matériel doit être retourné dans nos ateliers Pour tout...

Page 6: ...Mesures et Instrumentation Alimentation 0 à 30V continu Réf 281 048 FRANÇAIS 5 NOTES ...

Page 7: ...ton Allows rough adjustment of the output voltage Turn clockwise to increase voltage and anti clockwise to reduce it 3 Intensity adjustment button Allows rough adjustment of the output current 4 Voltage adjustment button Fine adjustment Permits fine adjustment of the voltage 5 Display Indicates the voltage 6 Display Indicates the current intensity 7 Output terminals The power supply is delivered w...

Page 8: ...or an extended period Do not use the appliance when it is cold its operating temperature must be between 0 C and 40 C Avoid sudden movement of the power supply from a warm to a cold place and vice versa otherwise there is a risk of condensation forming inside the appliance 3 2 Avoid damp and dust If the power supply is located in a very damp or dusty place operating problems can be expected The ra...

Page 9: ...use Use the correct type of fuse to protect the appliance against current overload If a fuse has blown find the cause with due care and replace the fuse with one of the correct rating If you do not use the right fuse not only will the appliance not work properly but the failure could become worse You must ensure you use the correct fuse Remarks 1 The intensity adjustment potentiometer must be posi...

Page 10: ...resent at the output terminals 5 Maintenance This appliance contains high precision components and must be handled and stored with the greatest care Clean the displays using a soft cloth The recommended storage temperature is 10 to 60 C 6 After Sales Service This material is under a two year warranty and should be returned to our stores in the event of any defects For any repairs adjustments or sp...

Page 11: ...Measurements and Instrumentation Power supply 0 to 30 V DC Réf 281 048 ENGLISH 10 NOTES ...

Page 12: ...une information technique Vous souhaitez un conseil d utilisation Vous avez besoin d un diagnostic urgent Nous prenons en charge immédiatement votre appel pour vous apporter une réponse adaptée à votre domaine d expérimentation Sciences de la Vie et de la Terre Physique Chimie Technologie Service gratuit 33 0 2 32 29 40 50 Hors coût d appel Aide en ligne www jeulin fr Rubrique FAQ Rue Jacques Mono...

Reviews: