background image

2. Technical information 

A. Condition of use

1. 

Temperature from -15° C  to +40° C 

2. 

Humidity from 20 % to 90 %  

3. 

Weather conditions relevant to working conditions

4. 

Natural and/or artificial lighting of the work site, >200 lux

B. Air compressor requirements

1. 

Pneumatic pressure   

 

16 bar maximum

2. 

Required air flow 

 

 

0.14 - 11 m3/min

3. 

Air hose fittings 

 

 

Cejn type

C. Operational capacities

1. Pushing 

force 

   0-200N

2. 

Pushing speed 

 

 

0-110 m/min

3. 

Fiber sizes 

 

 

 

0,5 mm to 6,5 mm

4. 

Pipe 

sizes 

   3-16 

mm

D. Electrical requirements

1. 

Power requirements   

 

18 V 4 Ah    

2. 

Power connection 

 

 

Hitachi standard

E. Physical specifications

1. Height 

    240 

mm

2. 

Length 

    170 

mm 

 

3. 

Width 

    120 

mm

4. 

Weight    2,2 

kg

F. Wheel drive specifications

1. 

Maximum pushing force is 200N

2. 

Adjustable clamp force

G. Pipecoupling requirements

1. 

Must withstand maximum air pressure of 16 bar

2. 

Must withstand axial loading and vibration

3. 

Must be a compression type coupler

4. 

Must fit snugly

5. 

Pipe ends must be cut off squarely and deburred

6. 

Pipe must be fully seated into the coupler

6

Summary of Contents for MJet V0 HD

Page 1: ...MJet V0 HD Product model type MJet V0 HD 18 V MJet V0 HD 18 V USER S GUIDE AND SAFETY MANUAL...

Page 2: ...rm or by any means including photocopying recording or other electronic or mechanical methods without the prior written permission of the publisher For permission requests write to the publisher addre...

Page 3: ...all safety information on this page and note specific safety requirements as explained by procedures in this manual Failure to follow these instructions could result in serious personal injury or dea...

Page 4: ...ormation 2 6 Safe operating practices 3 7 Unpacking the box 4 8 Set up the blower 5 9 Display functions 6 10 Crash test 7 10 Blower operations 8 11 Maintenance 9 12 Troubleshooting guide 10 13 EC Decl...

Page 5: ...interchanged to accommodate different pipe and fiber sizes The pipe is mechanically clamped between the duct clamps at the exit of the pipe clamp preventing movement in any direction Seals conform aro...

Page 6: ...d 0 110 m min 3 Fiber sizes 0 5 mm to 6 5 mm 4 Pipe sizes 3 16 mm D Electrical requirements 1 Power requirements 18 V 4 Ah 2 Power connection Hitachi standard E Physical specifications 1 Height 240 mm...

Page 7: ...protective equipment 2 Ensure no personnel are in the destination access vault during the blowing operation C Electrical devices The motor controller and digital display are electrical devices Electr...

Page 8: ...e charger has 2 indicator lights to represent the status of the battery during the charging process When connecting a discharged battery the red light will illuminate to indicate the bulk charge state...

Page 9: ...tall fiber in wheel drive and tighten Feed the fiber in the wheel drive and through the rear fiber guide Tighten wheel drive using the down screw knob to ensure even pressure on the fiber Tighten down...

Page 10: ...and these values vary depending on duct I D Always wear protective equipment hard hat safety glasses safety shoes and work gloves IMPORTANT For the Crash Test to work properly use the same size fiber...

Page 11: ...may be helpful to guide apply back tension to the fiber using your hand at the fiber entrance of the machine to maintain control over the fiber 1 Set wheel clamp force to the lowest possible setting t...

Page 12: ...ean after each use or when necessary Disconnect power supply and exhaust any air pressure before servicing any component on the MJET V0 HD Avoid handling leaking couplings valve seal or inadequately s...

Page 13: ...ated 4 Notify supervisor about problem and determine a solution accordingly Wheels does not pull the fiber 1 Assist the reel by pushing the fiber of the reel The fiber run is hard to restart after 1 P...

Page 14: ...14 11 EC Declaration of Conformity...

Page 15: ...15 12 Notes...

Page 16: ...MJet V0 HD 18 V USER S GUIDE AND SAFETY MANUAL Version 2021 12...

Reviews: