background image

11. Delete session, save and go back or save and send

• After you closed a session you can choose to:

 

- Delete session

 

 

If you delete it you won't be able to get it back.

 

- Save and back

 

 

If you chose this, the protocol will be stored in 'Old sessions'.

 

- Save and send

 

 

If you chose this, the protocol will be stored in 'Old Sessions' and you will have 

 

 

the possibility to send the protocol to a mail account (for example if you wish 

 

 

 

to send it to the network owner or to an installer or save it in the cloud).

• To send the session to a mail account, you need to set up your own mail account, see section  12 for 
  more information about this. 

12. Technical information

Tablet

The tablet controlling the JetLogger is an industrial Galaxy tablet from Samsung designed to work 
in the field based on the Android system. The tablet has a slot for SIM-card if you like to be direct 
connected via mobil signal. The SIM-card you must purchase separate by your local telecom 
provider. The tablet is protected and placed in the JetLogger Box. The tablet can be removed 
from the box to make it easyer to read from. Please observe that the tablet is not charged if it is 
removed and the tablet must be connected with the USB cable to receive data from the machine. We 
recommend using the tablet pen for typing in the data.

GPS/Google maps

Via GPS the JetLogger can identify the exact location. If you press the text 'Location GPS' on the Protocol 
screen you will start Google maps and see the location on a map.

How to find the serial number on the tablet

Start the tablet and go to settings, look for 'About Tablet'. Here you have all the data concerning the 
tablet, such as the serial number.

Safety shutdown

The JetLogger system has a safety shutdown function, stopping the cable installation if the set value of 
the pushing force is exceeded. Please observe that after a safety shutdown the air supply to the motors 
(on model V1, V2, V3) MUST be turned down to zero. If not, the machine will start over with the speed/
pushing force from before the safety shutdown, creating possible damage to the cable. 

15

D A R E   T O   D O   I T   D I F F E R E N T L Y .

Summary of Contents for JetLogger V0

Page 1: ...D A R E T O D O I T D I F F E R E N T L Y JetLogger Product model type V0 V1 V2 V3 V 21 04 JETLOGGER SAFETY INSTALLATION AND OPERATIONS MANUAL...

Page 2: ...rm or by any means including photocopying recording or other electronic or mechanical methods without the prior written permission of the publisher For permission requests write to the publisher addre...

Page 3: ...r operations other than those described in this manual are considered dangerous and are discouraged Use of this machine for work other than what is intended relieves the manufacturer from any responsi...

Page 4: ...protocol 5 9 Set up tablet for new session 6 10 Do a new session with last used data 7 12 Open old session 8 13 Add a new pipe to tablet 9 14 Add a new cable to tablet 10 14 Delete session save and go...

Page 5: ...tion by GPS the JetLogger is monitoring for every 1 0 m the air pressure speed distance and pushing force This parameter is presented live on the tablet giving the user a full view over the process Ex...

Page 6: ...le Connect battery or power supply to the V0 Connect compressor to V0 make sure the air valve is closed Insert the pipe and cable used for the job Start by switch on the V0 by pushing the power button...

Page 7: ...the Log Box Connect compressor to the fiber blowing machine remember to close the air valve and set the emergency valve and regulator in closed position Insert the pipe and cable used for the job Sta...

Page 8: ...ween 1 Crash test protocol Used to perform a crash test and find max pushing force 2 New session Used when a new job must be documented 3 New session with last used data Used when a job must be docume...

Page 9: ...ou will do crash test When all information is filled out the Start session box turns green Press on it to start If software is asking for connection to SparkFun Pro Micro press OK You can now start yo...

Page 10: ...tion of the pipe Type in the pipe temperature use a separate temperature measuring equipment Chose cable You will see the list of cables that are stored in the memory If not already stored you can use...

Page 11: ...k Yes in the box please read about safety Shutdown in section 12 Information about the humidity and temperature will come automatically from the BluSensor When all information is filled in the Start s...

Page 12: ...art your installation and the system will document the job When you are finished with your installation press on End session Note the meter marking on cable and fill out this in the protocol under End...

Page 13: ...en or Send your saved sessions If you want to open a session just press Open for that session you want to open You can see the full documentation for that specific session If you want to send or delet...

Page 14: ...about the pipe and press save Now you can choose this pipe in the protocol 10 Add a new cable to tablet If you want to add a new cable to the JetLogger press on Add cable in the main menu and this men...

Page 15: ...The tablet is protected and placed in the JetLogger Box The tablet can be removed from the box to make it easyer to read from Please observe that the tablet is not charged if it is removed and the tab...

Page 16: ...e with a inner diameter size of 8 00 mm the OCPC system will only present the cables which are optimal for this pipe size It is possible for you to override the recommendation from the OCPC system if...

Page 17: ...ight 11 4 kg For V1 V2 V3 logbox battery included 1 Height 180 mm 2 Length 445 mm 3 Width 250 mm 4 Weight 4 1 kg 17 D A R E T O D O I T D I F F E R E N T L Y 13 Documentation and disposal Ordering doc...

Page 18: ...14 EC Declaration of Conformity 18 D A R E T O D O I T D I F F E R E N T L Y H kan Johansson...

Page 19: ...15 Notes 19 D A R E T O D O I T D I F F E R E N T L Y...

Page 20: ...D A R E T O D O I T D I F F E R E N T L Y JETLOGGER SAFETY INSTALLATION AND OPERATIONS MANUAL Version 2022 11...

Reviews: