Appendix
JetWeb
10.3 Direct Current Input Connectors and Output
Connectors
Operating Parameters (EMC) - Emitted Interference
Parameters Value(s)
Standard
Signal and Control
Connection
Direct Voltage Supply
Inputs and Outputs
Frequency bands:
0.15 to 0.5 MHz,
limit 40 to 30 dB
0.5 to 30 MHz,
limit 30 dB
(class B)
DIN EN 61000-6-3
Operating Parameters (EMC) - Immunity to Interference
Parameters Value(s)
Standard
RF, asymmetric
Frequency band 0.15 - 80 MHz
Test voltage 3 V
AM 80 % with 1 kHz
Source impedance 150 Ohm
Criterion A
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-6
Bursts
Test voltage 2 kV
tr/tn 5/50 ns
Repetition rate 5 kHz
Criterion A
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-4
Voltage Surges,
asymmetric
(line to earth),
symmetric
(line to line)
tr/th 1.2/50 µs
Common mode launching 1 kV
Push-pull launching 0.5 kV
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-5
44