background image

5

© 2013 Jetta Corporation

All rights reserved. REV 06/2013

www.jettacorp.com

owner’s manual

installation instructions

receiving:

Immediately upon receiving your Affinity bath, inspect it thoroughly for freight damage. If damage is found, please 

note on bill of lading and contact JETTA Corporation immediately. The surface should be protected at all times to 
prevent scratches. 

Do not carry unit by the piping as this may cause leaks. 

• 

Check color match before installation.  

• 

Nothing should be placed in bath that would scratch or break it. 

• 

Workmen in bath should be in stocking feet only.

• 

testing:

Water test your unit prior to installation. Set the tub on a level surface where it can be drained after testing. Insert 

drain fitting and fill to the overflow. Make sure all fittings, through walls and piping are water tight. While each unit is 
leak tested at the factory, the process of shipping and handling may loosen joints. If there are leaks, mark the spot(s), 
drain and repair with GE Silicone Sealer (fiber glass to PVC) or PVC cement (PVC to PVC).  Repeat test when dry.

rough-In:

Test fit the tub, and verify dimensions. Your Affinity bath should be installed in a bedding compound, preferably a 

mortar mix or thin set, which should be distributed under the base to provide maximum support and even weight 
distribution. Do not use foam, sand or drywall mud. When leveling, prepare a bed of moist mortar in the area where 

bath is to be installed. Place equally spaced mounds of bedding compound, about one foot apart, 2” to 4” tall - this 
should be about the diameter of a three pound coffee tin (8”-10”). When the bottom of the tub comes in contact 
with the bedding compound, it should compress the mounds to a 1” to 3” layer while the tub should lightly rest on 
top of the tub deck. Once the bedding compound drys, all of the weight will be carried through the floor of the tub, 

not suspended by its lip. Carefully level the unit, ensuring that uniform support is given to all areas of the base 
and that no portion of the lip is bearing weight. 

DO NOT SUPPORT THE WEIGHT OF THE BATH BY THE RIM! 

Since your Affinity bath has a pre-leveled lip that accounts for the sloped floor towards the drain, the 1” x 1” drain board 

attached to the bottom of the tub does not need to be removed. It is recommended that plastic is laid between the bed-
ding compound and the bath, in case removal of the bath is ever necessary.

Installation:

Use union connections only for the pump. Do not overtighten. Make sure the O-rings on the pump are in place. 

Hand tighten pump fittings. Do not use a wrench, channel locks, or pipe dope (teflon paste). Pump must be located 
between 1/2” to 1 1/2” above suction fitting. Make sure suction line will drain from pump to bath. A minimum 
access panel of 14” x 10” must be provided in case the pump needs to be serviced at a later date. The air switch 

must be located on or near bath, with access available. Check to ensure that the air hose is plugged into the switch 
that is located at the back of the rectangular box on top of the motor. For additional safety, a ground-fault circuit-
interrupter must be added. Faucets may be installed through the wall or mounted on the bath. Insert drain and 

overflow to waste line. 

After installation, fill the bath and let stand 3 - 4 hours (operating it for at least 30 

minutes) to double check that it is still water tight.

Summary of Contents for Affinity

Page 1: ...www jettacorp com Owner s Manual Installation Guide This manual is to be given to the product owner and should be kept for future use A F F I N I T Y C O L L E C T I O N...

Page 2: ...s FACTS THAT MAKE JETTA YOUR BEST CHOICE 3 SAFETY INSTRUCTIONS ELECTRICAL REQUIREMENTS 4 INSTALLATION INSTRUCTIONS 5 MAINTENANCE CLEANING 6 OPERATING INSTRUCTIONS 7 TROUBLESHOOTING 10 LIMITED FACTORY...

Page 3: ...the plumbing gives added support and cuts down on noise and vibrations The fact that there is no hazardous heating element in contact with the bath water is also an important safety feature which will...

Page 4: ...ure and circulation The use of alcohol drugs or medication before or during whirlpool use may lead to unconsciousness with the possibility of drowning Persons suffering from obesity or with a medical...

Page 5: ...fee tin 8 10 When the bottom of the tub comes in contact with the bedding compound it should compress the mounds to a 1 to 3 layer while the tub should lightly rest on top of the tub deck Once the bed...

Page 6: ...in small circles until scratches or abrasions are gone then wipe with a dry cloth until the original gloss is restored Repairs of any kind if necessary should be done by qualified acrylic experts 3 Pr...

Page 7: ...ub with your installer We recommend that water temperature not exceed 102 F 2 We also recommend consulting physi cian for specific temperature and length of use limitations depending on individual hea...

Page 8: ...2013 Jetta Corporation All rights reserved REV 06 2013 800 288 7771 8 owner s manual operating instructions for optional air bath feature Optional Heated Quiet Flo Blower...

Page 9: ...9 2013 Jetta Corporation All rights reserved REV 06 2013 www jettacorp com owner s manual Verbiage Copy operating instructions for optional air bath purge cycle...

Page 10: ...on tub or the air switch on motor Motor comes on and hums This condition may be a symptom of the pump shaft being stuck due to the build up of minerals or debris collecting on the impeller on the pump...

Page 11: ...ndustrial baths from date of manufacture 4 The equipment warranty is valid for five 5 years for residential baths and one 1 year for commercial hotel or industrial baths from date of manufacture 5 Thi...

Page 12: ...425 Centennial Blvd Edmond OK 73013 Corporate 405 340 6661 Toll Free 800 288 7771 Fax 405 348 9745 www jettacorp com REV 06 2013 tub label A F F I N I T Y C O L L E C T I O N...