4. Remove the valve spring retainer and valve
spring (Figure 75).
5. Lift the assembly off of the suction valve and
set the suction valve aside.
6. Insert a small screwdriver under the dis-
charge spring (Figure 76). Carefully rotate the
screwdriver until the spring releases from the
groove.
Note:
3015 valves are equipped with a
retaining ring to secure the discharge
spring (Figure 77).
7. Remove the discharge valve and discharge
spring.
8. Inspect the valves. Refer to “Valve Inspection”