Page 4

2. Components and specifications - single sided

20MM

A Jetmaster firebox may be installed without a gather in an existing brick chimney only where it is in
good working order, structurally sound and passes a static smoke test.

Gather must be securely bolted to the unit (if used)

Optional 3 and 4 sided 100mm surrounds are available. Add 100mm to B measurement for coverage

Gather

Single sided

Unit

MODEL

A

B

C

D

E

F

G

H

I

440

470

510

330

610

200

200

80

190

140

500

570

600

350

650

200

200

90

230

120

600

670

700

350

650

200

200

90

230

120

600 LOW

670

700

350

600

200

200

90

230

120

700S

770

800

350

650

200

200

90

230

120

700SH LOW

770

800

350

600

200

200

90

230

120

700 D

770

800

400

700

200

225

100

250

150

850

920

950

450

750

220

250

130

300

150

850 LOW

920

950

450

700

220

250

130

300

150

1050

1120

1150

500

800

240

300

150

320

180

1050 LOW

1120

1150

500

750

240

300

150

320

180

1050 LOW LOW

1120

1150

500

700

240

300

150

320

180

Measurements are in mm and provided as a reference only.

Due to the nature of thick welded steel, it is normal and expected for some imperfections and slightly out of square components. It is recommended to not

begin construction of cavity or flue penetration points until after the unit is in place on site.

A

B

C

D

E

F

G

H

I

50MM

Summary of Contents for UNIVERSAL 440

Page 1: ...only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not...

Page 2: ...ction and contents WARNING Page Section Information 2 3 1 Getting started 4 2 Components and specifications Unit and Gather 5 2 Components and specifications Surround Cowl Logpan and Screen 6 3 Timber...

Page 3: ...height of chimney between 14 16 feet 4 26 4 88m measured from the base of the appliance C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate p...

Page 4: ...ate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the app...

Page 5: ...230 120 600 LOW 670 700 350 600 200 200 90 230 120 700S 770 800 350 650 200 200 90 230 120 700SH LOW 770 800 350 600 200 200 90 230 120 700 D 770 800 400 700 200 225 100 250 150 850 920 950 450 750 22...

Page 6: ...chieve a visual design and such cowls can be used but must not restrict airflow from the flue pipe casings For gas applications an AGA approved cowl must be used C D Measurements are in mm and provide...

Page 7: ...0 1375 1170 575 850 LOW 1325 1170 575 1050 1425 1370 625 1050 LOW 1375 1370 625 1050 LOW LOW 1325 1370 625 Note Timber framing should be constructed using normal framing methods Image above is an exam...

Page 8: ...Hebel Powerpanel Clay bricks 75mmx110mmx230mm if used as a hearth must be laid on the 110mm edge combined with 12mm cement sheet See joint AS NZS 2918 2018 3 3 2 Bricks on the 75mm face is insufficie...

Page 9: ...to outer flange to 300mm above opening and 150mm to the sides Optional 3 or 4 sided 100mm surrounds are available If elevating unit above finished hearth level lower wall finishing must also be non co...

Page 10: ...tion cap away from trees adjacent structures uneven roof lines and other obstructions Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions tha...

Page 11: ...r at crimped joins Fix outer non active flues to active inner flues use 3 x 25mm self tapping screws through outer flue at bottom at each join and on top at each join As an alternative rivet 4 x 25mm...

Page 12: ...t is suggested an experienced builder to do the work as the sides support inner flues of the chimney NOTE Allow 1 5mm expansion gap for all materials 3 Repair any cracks or cavities in the recess espe...

Page 13: ...masonry overhangs the smokeholes ensure at least 200mm clearance above the unit Ensure seal between brick edge and firebox front optional surround likely required to assist forming this seal as per be...

Page 14: ...side towards you with the steel handle provided 2 In firebox lay your fire lighters 10 to 15 centimetres apart depending on the size of your firebox Do not use newspaper as a fire lighter On units th...

Page 15: ...S NZS 2918 General notes Fuels The quality of firewood is extremely important How long a tree has been felled or dead for does not indicate how dry the wood is The best way to dry wood is to split it...

Reviews: