Page 5
2. Components and specifications
Bird cowl
A
B
MODEL
A
B
C
D
440
425
230
425
430
500
480
255
495
455
600
575
255
595
455
600 Low
575
255
595
405
700 S
675
250
695
455
700 Sh Low
675
250
695
405
700 D
675
315
695
500
850
820
350
845
545
850 Low
820
350
845
495
1050
1025
400
1045
590
1050 Low
1025
400
1045
540
1050 Low Low
1025
400
1045
490
Logpan
Firescreen - optional
For solid fuel applications only, a rotating bird cowl will assist in
preventing the effects of downdraft as it turns with the direction of wind.
Other solid fuel cowls may be desired to achieve a visual design and such
cowls can be used but must not restrict airflow from the flue pipe
casings.
For gas applications an AGA approved cowl must be used.
C
D
•
Measurements are in mm and provided as a reference only.
•
Due to the nature of thick welded steel, it is normal and expected for some imperfections and slightly out of square components. It is recommended to not
begin construction of cavity or flue penetration points until after the unit is in place on site.
Optional 100mm surround
The surround should be installed before sliding the
unit into it’s final position.
Lift the surround above the fireplace outer flange and
locate the external tabs over the flange and lower
into place. Ensure the top folds clip on securely.
Tabs secure to outer flange