Jetmaster QUADRO Installation Instructions Download Page 3

Appliance must sit on a

non-combustible base

 

eg. 75mm 

Hebel 

or 

100mm

 concrete

.

 

40

mm packers are required

.  

 

Allow 5mm gap between plaster and flange to 

ensure stainless steel cover can be fitted to the box.

DO NOT PLASTER OVER THE FLANGE

FOR DETAILS OF FLOOR PROTECTION (HEARTH ) 

SEE PAGE 5 OF THIS DOCUMENT

1.ODQ.3C

min. 25mm clearance

25

25

min. 25mm clearance

B + recessed

Masonry or Hebel block

minimum ‘A’

‘X’ - Refer to Table 2 for Floor Protector dimension

RECESS REQUIRED (40mm Min.  100mm Max)

‘Y’ - Refer to Table 2 for 

Floor Protector dimension

Air Vent

Air Vent

min. 2 x 100 x 

200

mm wall of floor 

mounted air vents

 top and bottom

Jetmaster

Flange

Fig. 

4

Drawings Not 

To Scale

Fig. 

2

PLAN

CROSS SECTION

B + recessed

Concrete Lintel 

Secure firebox with 2 x 6mm 

dynabolts for earthquake 

restraints

or Hebel Block

RECESSED REQUIRED

40mm Min. - 100mm Max recess

Rock-wool 

insulation

Allow 5mm gap around all 

four sides of the firebox to 

fit Stainless Steel cover & 

allow

 

for firebox 

expansion

.

Fit 

40

mm Hebel packers

 

placed

 under the appliance

IMPORTANT

No combustible material into chimney chase

20

20

C- D

temporary lintel height

* A  minimum  75mm  thick  Floor  protector  is  only  required  if  finished  surface  is  combustible  e.g:  timber

 

decking

Please note that these dimensions (based on Masonry margins) are the absolute minimum sizes - widths (A & B) maybe 

increased if desired. 

If you intend on recessing the firebox, please add the recess value to 

Dimension ‘B’. MINIMUM RECESS = 40 / MAXIMUM 

RECESS = 100mm

 

It is important to ensure the Jetmaster firebox is seated at the required finished floor protector level.

DO NOT COVER AIR VENTS WITH MESH - as this reduces air flow, use specific external air vent covers that provide sufficient 

air.

All

ow

  5mm 

  gap  around  all  four

 

sides  of  the  firebox  to  fit  the  Stainless  Steel  Weather  Cover

.  i.e. do not plaster 

up to the flange of the firebox, see Fig 

4

.

Fig. 

3

N

on-combustible 

raised 

floor 

protector must 

be

 75mm Hebel 

or 

100mm

 concrete

Appliance must sit on a

non-combustible base

 

eg. 75mm 

Hebel 

or 

100mm

 concrete

.

 

40

mm packers are required 

Reviews: