Jetmaster Mark 2 Gas Coal Installation Instructions Manual Download Page 12

PROBLEM 

POSSIBLE  CAUSE 

SOLUTION         

 

 

 

Pilot will not light 

No gas 
 

1)Bleed air from gas line. 
2)Check stop cocks are in on 
position.(No blockage in line) 
 

 

 

 

 

Wrong inlet pressure 

Adjust inlet pressure with main burner 
running.(see diagram) 

 Defective 

spark 

electrode. 

Replace electrode if the insulator is 
cracked or the tip is corroded. Verify that 
the spark gap between the pilot and the 
electrode is correct. 

 

Defective piezo wire. 

Replace piezo wire if insulation is 
damaged , or the wire is broken or 
corroded. 

 Safety 

interlock 

function engaged. 

Allow thermocouple to cool until the mV 
drops below the hold in requirements of 
the safety magnet,(30 seconds or less). 
Re-light pilot. 

Pilot will not hold 

Wrong inlet pressure. 

Adjust inlet pressure with main burner 
running (see diagram). 

 

Pilot adjustment screw 
not properly adjusted. 

Refer to item # 7 in the set-up 
guide.(also see diagram) 

 Thermocouple 

or 

thermo-generator not 
properly inserted into 
the pilot housing. 

Refer to item #3 in the set-up guide.(see 
diagram) 

 Thermocouple 

or 

thermo-generator has 
film build-up on tip. 

With the thermocouple and thermo-
generator tips cool, clean the upper 3/8” 
with a very fine emery cloth.  

  

Electrical resistance too 
high. 

Using a very fine emery cloth, clean 
thermo-generator and thermocouple 
connections at valve. Tighten 
thermocouple into valve hand tight, plus 
¼ turn with a wrench. 

 Defective 

thermocouple(mV Plus 
systems) 

Verify that thermocouple is not kinked 
or damaged. Check open circuit voltage 
of thermocouple. Voltage should be 
between 18mV and 28mV. If voltage is 
less than 14mV, replace thermocouple. 

 Defective 

thermo-

generator.(Millivolt 
system) 

Refer to item # 7 in the set-up guide. 

Summary of Contents for Mark 2 Gas Coal

Page 1: ...Installation instructions Jetmaster Mark 2 Gas Coal Pebble with Millivolt Control...

Page 2: ...imney should be tested and proven to have an adequate updraft which shall be sufficient to remove all waste products of combustion A minimum cross sectional area of 40 000 sq mm is required with a min...

Page 3: ...ol knob on right hand side of valve Depress and turn control knob FIG 1 to the PILOT position FIG 4 Depress the control button and ignite with piezo ignitor FIG 2 whilst keeping control knob firmly de...

Page 4: ...HOW TO ADJUST GAS PRESSURE...

Page 5: ...of coals in a honeycomb pattern to form an elongated pyramid Lay the coals pebbles so that some irregularity to the pile through which the flames may lick is created Your aim is to build windows into...

Page 6: ...which has been designed to ensure a proper draw and to eliminate emission spillage 2 Initially the Jetmaster coal pebble fire may burn with a slightly blue flame After approximately 20 minutes the fir...

Page 7: ...existing masonry fireplace or equivalent approved open fireplace The gas fire consists of an outer decorative grate which houses a mild steel burner tray A front plate is provided to cover controls CA...

Page 8: ...s welded onto a 4 5mm guage mild steel frame to provide the appearance of a solid fuel basket grate A 1 6mm guage folded mild steel tray is located within the basket grate It is welded to the back of...

Page 9: ...located under the burner tray Burner A folded mild steel tray with deflector plate A cast iron venturi tapered mixing tube is welded to the base through which gas is introduced Pilot S I T Pilot asse...

Page 10: ...For LPG the appliance regulator requires removal Note pressures on data plate for natural and LP gas and adjust accordingly The test point is located on the SIT valve HEATING SYSTEM Vermiculite Is var...

Page 11: ...the safety magnet Millivolt systems utilise power from the thermo generator 7 After the pilot has been lit for approximately three minutes and only the thermo generator wires connected to the main ope...

Page 12: ...ure with main burner running see diagram Pilot adjustment screw not properly adjusted Refer to item 7 in the set up guide also see diagram Thermocouple or thermo generator not properly inserted into t...

Page 13: ...and TP If the voltage is above 110mV and the safety magnet does not hold replace the valve Pilot injector blocked Replace injector with a new injector of the exact size and type Pilot drops out Wrong...

Page 14: ...at wiring except substitute the words wall switch where the word thermostat appears in the instructions Excessive wire resistance Make certain that all mV connections are made using wire of the proper...

Page 15: ...Notes For further information contact Jetmaster Australia 10 Martin Avenue Arncliffe NSW 2205 T 02 9597 7222 F 02 9597 7622 E sales jetmaster com au W www jetmaster com au...

Reviews: