Technical Data
Gas Inlet Connection:
5/16" (8 mm) O.D. tube with olive fittings into a test
point on the right-hand side of the Gas Convector.
Regular LPG:
2,75 Kpa inlet pressure.
Gas Control:
BM 733 model for both the 550 and 700 burner.
Baby Sit Manual Control Valve fitted to the 850 burner.
These gas controls are located centrally underneath the
burner.
Pilot Markings:
Oxygen depletion system fitted.
LPG 9221 O.P. Controls.
Pilot Turnoff Valve:
Integral with BM valve fitted to 550 and 700 burner.
Integral with Baby Sit Manual Control Valve fitted to 850
burner.
Pressure Test Point:
5/16" (8mm) diameter nipple located on the inlet gas
supply on the 550 and 700 burner.
Test point on the Baby Sit Manual Control Valve on the
850 burner.
Gas Cylinder Size:
1 x 48kg bottle for 550-700 De Luxe Gas Convector.
2 x 48kg bottle for 850 De Luxe Gas Convector.
INSTALLATION & OPERATING INSTRUCTIONS
2
INSTALLATION AND OPERATING INSTRUCTIONS:
550, 700 & 850 DE LUXE
Note: The total width
measurement including
gather is A + 50
H
50
50
A + 50
A
D
B
C
J
I
G
F
E
MODEL
& SIZE
NOMINAL
FLUE SIZE
mm
A
B
C
D
E
F
G
J
H
I
Ø
550
316
650
200
105
625
420
90
200
200
200
700
316
650
200
105
625
420
90
200
200
200
850
316
650
200
105
625
420
90
300
200
250
ROUND
EQUIVALENT