  Do not dismantle or drop the module and do not remove any

  attached nameplate or components from the module.

  Do not bend or twist the module.

  Do not apply paint or adhesive to module top surface.

  Do not use pointed or sharp objects with the module.

  Artificially concentrated sunlight shall not be directed on the  

  module.

  Precipitation can run off through small openings on the  

  back side of the module. Make sure that the openings are
  not masked after mounting.

  Do not wearing rings, watches, or metal jewelry during instal-

  lations.

9) Hazard Warnings

Danger of death from electric shock!

PV modules generate electricity as soon as they are exposed to 
sunlight. One module generates a safe, extra low voltage level, 
but multiple modules connected in series (summing the voltage) 
or in parallel (summing the current) represent a danger. The fol-
lowing points must be noted when handling the solar modules 
to avoid the risk of fire, sparking and fatal electric shock.

 

Do not insert electrically conducting parts into the plugs or  

  sockets!
•  Do not fit solar modules and wiring with wet plugs and 
  sockets!
•  Exercise utmost caution when carrying out work on wiring  
  and safety equipment (use insulated tools, insulated gloves,  
  etc.)!
•  Do not use damaged modules! Do not dismantle modules!  
  Do not mark on the rear of the module using sharp objects!
•  Exercise utmost caution when working on wiring and the  
  inverter. Be sure carefully to follow manufacture’s installation  
  instructions!

Danger of death from arcing!

Modules generate direct current when light shines on them. An 
electric arc may be generated when connectors are used to 
turn the circuit on or off. We therefore recommended covering 
modules with a lightproof cloth during installation. When brea-
king a connected string of modules (e.g. when disconnecting 
the DC line from the inverter under load), a lethally strong arc 
can occur.

 

Never disconnect the solar generator from the inverter while

  the inverter is connected to the mains grid—remove the fuse
  from the AC side on the inverter first!
•  Ensure the connectors are clean and have not been conta-
  minated and that the electrical connection and mechanical
  joint are good!

Summary of Contents for JTxxxSFb series

Page 1: ...Installation Manual Visionary green energy...

Page 2: ...enance Jetion reserves the right to update the product specifications or this Installation Manual without prior notice 1 Certificates requests 1 1 IEC 61730 Jetion modules are designed to fulfill the...

Page 3: ...other modules When a bypass diode is wired in parallel with the series string the forced current will flow through the diode and bypass the shaded module thereby minimizing module heating and array c...

Page 4: ...system The modules are Class C You can mount them over a Class C B or A roof The amount of area the modules cover may degrade the roof s original fire rating in some loca tions Do not install modules...

Page 5: ...2 12 12 12 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 2 5 3 2 5 3 2 5 3 2 5 3 2 5 3 2 5 3 2 5 3 2 5 3 M8 Screw Middle Modules Installation Frame long side Mounting rail Clamp The movement of the...

Page 6: ...2 725x942 1176x942 JT SFa b JT SAa b JT SAa b Black JT SBa b JT PFe JT SFc JT PEe JT SEc JT PDe JT SDc JT SDc Black JT PCe JT SCc JT SCc Black JT PAe JT SAc Mono Mono Mono Poly Mono Poly Mono Poly Mon...

Page 7: ...ons we recommend cleaning the modules using plenty of water from a hose with mild detergent and using a gentle cleaning implement a sponge CAUTION DON T USE DETERGENTS CONSISTING OF ABRASIVE ACETONE O...

Page 8: ...ically conducting parts into the plugs or sockets Do not fit solar modules and wiring with wet plugs and sockets Exercise utmost caution when carrying out work on wiring and safety equipment use insul...

Page 9: ...ww jetion biz JETION SOLAR CHINA Jetion Solar China Co Ltd No 1011 Zhencheng Road Shengang Jiangyin Municipality Jiangsu Province 214443 Peoples Republic of China Phone 86 510 8668 7300 Fax 86 510 866...

Reviews: