PAGE 53 of 54
Special Function
Temperatur adjustment
After a replace of a temperature sensor it need be necessary to run a temperature
calibration
How to manage:
The turbine must be at ambient temperature (ca. 21°C) !!!
Press and hold the
„Select Menu“ key on GSU
, then
swictch on ECU
(receiver).
Instead of
„Select Menu“ key of GSU, it’s possible to press the little key on the LED-
board.
The LED´s indicate the following blink sequence :
LED
Blink Sequenz
Standby
(yellow)
Pump running
(red)
OK
(green)
The dispaly of GSU indicate simultanously :
Release Key to
„Learn RC“
While this sequence hold the key
„SelectMenu“don’t realease it !!!!
Release the key if the three LED´s indicate this blink sequence:
LED
Blink Sequenz
Standby
(yellow)
Pump running
(red)
OK
.... (green)
The Display of the GSU indicate simultanously:
“Release Key to Calibrate Temp“
after releasing the key on the GSU the temperature calibration runs.