PAGE 44 of 54
Smoker Flow
Only available by connected
Bus-pump
.
The smoke flow can be adjusted in a range of 0-100%.
Additional is shown the quantity of flow in milliliters (ml).
LowBat Warning
Battery warning function, Enabled/Disabled
Default = Disabled
Fueltank size
Actual capacity of the fuel tank in ml
LowFuel Limit
Fuel level (ml) to activate the fuel warning function.
LowFuel Warning
Fuel warning function, Enabled/Disabled
Default = Disabled (OFF)
AUX-channel func
The AUX-channel (3-step switch) can be used for optionally special features or
disabled even for single-channel operation.
ON,TrbCtrl ON
:
Aux channel enabled for turbine control
ON.TrbCtrl OFF
:
Aux channel enabled for speed limiter functions and/or Smoker.
Turbine control disabled. The Aux channel is used only for speed limiter
and/or smoker functions. The turbine control takes place by Single Channel
Mode
NOT USED
:
Single Channel Mode.
Totally disabled AUX channel input for turbine control, speed sensor and
smoker functions. AUX channel wire must not be connected to the receiver in
this mode. In case of a connected a air-speed sensor the Maximum Limit
Speed is still active and limits the maximum speed of the plane. This safety
function can’t be disabled.
Fail Safe delay
Delay in seconds before Fail-Safe function will be activated.
While this time the turbine speed run on the last valid stick pulse
(
→HOLD
)
adjustable range = 0.1 -20.0 seconds.
After expiration of this term the Fail Safe Time Out starts. (see next point)
Fail Safe Time Out
Delay in front of Fail Save cut off.
While this time the turbine speed is set to the Fail Save RPM (next point)
Is there no valid pulse after the expiration of this term the turbine will be cut off by
the ECU. Range 0.1-20 seconds.
Fail Safe RPM
Programmable turbine speed for the Fail Safe Time Out procedure.
Range from minimum RPM to maximum RPM.
Aux-ch Smoker Ctrl
The ECU can directly control a smoke valve or a Smoke pump for injection of
smoke fluid into the exhaust blast to generate smoke.
You can use the shut off valve (Part# 61106-00) as smoke valve. For smoke
pump you can use any Jetcat Smokerpump
AUX-channel programming for smoke function ( 3-step switch)
Settings:
DISABLED
Smoke solenoid is not used
→ valve is constantly closed
Open if AuxSw=0
Smoker-valve is open if:
Turbine is running and the AUX switch (3-Pos. switch) is brought to lower position
(“off” position)
To be able to use this function its necessary that the
AUX-channel func
is
activated by
ON,TrbCtrl Off
(see above).
That is to say the Aux switch is enabled for smoke function but not for turbine
control.
Open if AuxSw=2
Smoker -valve is open if: